SonixGPS影像穿刺定位系统在经皮肾镜取石术中应用的早期经验

Initial clinical experience of real-time ultrasound-guided percutaneous nephrolithotomy using the SonixGPS guidance positioning system

摘要目的 探讨SonixGPS影像穿刺定位系统在PCNL中应用的可行性及安全性.方法 选取2012年5月上尿路结石患者15例,男8例,女7例.年龄33 ~ 72岁,平均43岁.患者术前均行KUB、彩色多普勒超声、CT和(或)IVU等检查.其中11例伴有不同程度的肾积水;合并尿路感染4例,术前给予积极抗炎治疗;孤立肾2例.肾多发性结石7例,鹿角形结石3例,输尿管上段结石3例,肾结石合并输尿管上段结石2例.手术均采用全麻,取俯卧位,在SonixGPS影像穿刺定位系统的引导下,采用系统自带的16G穿刺针穿刺目标肾盏并扩张建立24 F标准皮肾通道,置入肾镜后应用EMS第四代气压弹道联合超声碎石清石系统进行碎石并吸出体外.结果 本组15例均一次穿刺成功并行一期碎石,手术时间30~ 115 min,平均45 min,经皮肾穿刺时间2~ 10 min,平均4 min.术中术后未出现大出血、肠道损伤、气胸等并发症.术后复查KUB,一期清石率为93% (14/15),1例有残余结石患者行ESWL治疗效果良好.结论 SonixGPS影像穿刺定位系统在PCNL穿刺前可预判和设计穿刺路径及角度,穿刺中可精准地看到穿刺针在组织中的穿刺轨迹,实时记录针尖位置,及时调整穿刺针的角度与深度,缩短了经皮肾穿刺技术的学习曲线.

更多

abstractsObjective To evaluate the feasibility and safety of SonixGPS guidance positioning system in PCNL.Methods In May 2012,a total of 15 patients with upper urinary tract calculi underwent PCNL by combining pneumatic and ultrasonic power (fourth generations of EMS) with the navigation of SonixGPS guidance positioning system.A 16 G proprietary needle was inserted into the fornix of targeted calyx under the navigation of SonixGPS,needle-beam alignment and correct trajectory were maintained by observing the indicator on the screen of SonixTouch ultrasound system.Preoperative imaging,including plain abdominal film of kidney,ureter,and bladder (KUB),ultrasonography,computed tomography with or without intravenous urography.Eleven patients had different degree of hydronephrosis.Four patients had urinary infection and received antibiotic treatment before operation.Of the 15 patients,7 had multiple calculi,3 had staghorn calculi,3 had upper ureteral calculi,and 2 had renal and ureteral calculi.Results The percutaneous renal access was successfully established in 15 patients and followed with phase Ⅰ lithotripsy.The mean operative time was 45 minutes,and the mean time of making a successful percutaneous access to the renal collecting system from an appropriate calyx was 4 minutes.Postoperative KUB demonstrated stone-free after primary procedure in 14 patients (93%),and 1 patient need extracorporeal shock wave lithotripsy.No severe complication was detected in all 15 patients.Conclusions Real-time ultrasound-guided PCNL using the SonixGPS guidance positioning system appears to be safe and efficacious.SonixGPS helps predict and clearly observe the needle's trajectory during invasive procedures.It helps improve skills in performing percutaneous access and reduces the learning curve for PCNL.The major limitation of this study was that it was a case controlled study and not a randomized double-blind study.These results should be proved by further large-scale and multi-center clinical study.

More
广告
  • 浏览869
  • 下载176
中华泌尿外科杂志

中华泌尿外科杂志

2013年34卷4期

272-275页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷