可转换型腔静脉滤器的临床应用观察

Clinical application of the convertible vena cava filter

摘要目的:评价可转换型腔静脉滤器临床应用的近期疗效、安全性和并发症。方法:回顾性分析2017年5月至2018年5月安置可转换型滤器患者的临床及随访资料。结果:103例滤器均成功置入。27例行滤器转换,26例转换成功(置入后5~145 d转换),所有转换滤器均无血栓形成、移位、倾斜、断裂或穿透静脉壁造成血肿等并发症。未转换原因主要包括年龄(18.4%,19/103)、高危人群的预防(12.6%,13/103)、有限的器官功能(9.7%,10/103)等。94例患者在术后6个月获得随访(91.3%),发现1例滤器内血栓形成,3例下肢静脉血栓加重但无下腔静脉闭塞,全部患者未再出现症状性肺栓塞。结论:可转换型腔静脉滤器可减少围手术期肺栓塞的发生率。年龄、有限的器官功能及高危人群的预防是低转换率的主要原因。

更多

abstractsObjective:To evaluate the short-term efficacy, safety and complications of convertible vena cava filter.Methods:The clinical and follow-up data of 103 patients who were placed with the convertible vena cava filter from May 2017 to May 2018 were retrospectively analyzed.Results:The convertible vena cava filters were successfully implanted in all cases. Twenty-seven cases underwent filter conversion, and 26 cases were successfully converted (5-145 days after implantation). None of them had complications such as thrombus formation, displacement, tilt, fracture or vein wall penetration. The reasons for no conversion included age (18.4%, 19/103), high-risk patients (12.6%, 13/103), limited organ function (9.7%, 10/103), etc. Ninety-four patients (91.3%) were followed up for 6 months. One developed thrombus in the filter, 3 developed lower limb venous thrombosis without inferior vena cava occlusion, and no patients were found with symptomatic pulmonary embolism.Conclusions:The convertible vena cava filter can safely and effectively reduce the incidence of perioperative pulmonary embolism.Age, limited organ function and high-risk of thrombosis are the main reasons for the low conversion rate.

More
广告
栏目名称
DOI 10.3760/cma.j.cn113855-20220711-00456
发布时间 2026-03-24(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览19
  • 下载1
中华普通外科杂志

中华普通外科杂志

2023年38卷4期

297-301页

ISTICPKUCSCD

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷