升主动脉替换联合三分支支架血管术中置入治疗急性A型主动脉夹层

Total aortic arch reconstruction with open placement of triple-branched stent graft for Stanford type A aortic dissection

摘要目的 总结升主动脉人工血管替换联合三分支支架血管术中置入治疗急性Stanford A型主动脉夹层的初步经验.方法 2008年6月至2009年9月20例急性A型主动脉夹层病人接受了升主动脉人工血管替换和三分支支架血管置入术.体外循环鼻咽温度降至20℃时,停止下半身灌注,经无名动脉近端升主动脉横断切口,将三分支支架血管置入主动脉弓和近端胸降主动脉真腔内,并将其分支支架血管依次置入左锁骨下动脉、左颈总动脉和无名动脉.将主干支架血管的近端与无名动脉近端的升主动脉切口重建后与替换近端升主动脉的人工血管端端吻合.结果 所有病人术中均顺利地置入三分支支架血管,平均体外循环(163.2±19.2)min,主动脉阻断(89.4±10.0)min,低流量选择性脑灌注和下半身缺血(32.7±6.6)min.术后出现短暂性神智障碍1例,急性肾功能衰竭1例.20例均治愈出院.术后3个月电子束CT检查结果示,主干支架血管及分支支架血管通畅、无扭曲;支架血管置入部位夹层假腔闭合;16例远端胸降主动脉夹层假腔闭合.结论 三分支支架血管术中置入是简化急性主动脉夹层者主动脉弓重建、提高手术安全性的一种有效方法.主要适应证为弓内内膜无破口而需主动脉弓重建的急性A型主动脉夹层病人.支架血管大小、分支支架血管间的距离选择和放置过程中避免内膜损伤是术中三分支支架血管成功放置的关键.

更多

abstractsObjective To report the primary experience of open placement of triple-branched stent graft for acute Stanford type A aortic dissection. Methods Between June 2008 and September 2009, 20 well-selected patients with acute Stanford type A aortic dissection underwent open placement of triple-branched stent graft for total arch reconstruction. When core cooling to a 20℃ nasophageal temperature, perfusion to the lower body was discontinued and the ascending aorta was transected at the base of the innominate artery. Through a transverse incision, the triple-branched stent graft was inserted into the true lumen of the arch and descending aorta, and each side arm of the stent graft was positioned one by one into the arch branches.The transected stump of the ascending aorta was reconstructed by inner proximal stent-free dacron tube of the main graft and outer teflon felt, and subsequently continuous anastomosis to the 1-branched dacron tube graft was made. Results Open placement of triple-branched stent graft was technically successful in all patients. The mean cardiopulmonary bypass time, aortic cross-clamp time and lower body arrest time were (163.2 ±19.2) min, (89.4 ±10.0) min and (32. 7 ±6. 6)min, respectively. Transient postoperative neurological dysfunction was observed in 1 patient and acute renal failure in 1 patient. All patients were discharged from the hospital. Their computed tomographic scans at 3 months postoperatively showed that all stent grafts were fully opened without distortion. In the vascular stent implantation site the dissected false lumen was eliminated. The false lumen of the descending aorta distal to the stent graft was closed with thrombus in 16 cases. Conclusion Open placement of triple-branched stent graft is a new effective technique for total arch reconstruction in acute type A aortic dissection. Patients have the indications of the extensive primary repair of the thoracic aorta without primary intimal tears in the arch may be the best candidates for this new technique. The size of the stent graft, the distances between two neighboring side arm grafts and the prevention of the intimal trauma during the placement are crucial for successful open placement of triple-branched stent graft.

More
广告
  • 浏览152
  • 下载340
中华胸心血管外科杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷