医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

共聚焦激光扫描检眼镜眼底成像与传统眼底彩色照相对老年人黄斑前膜检出结果比较

Comparison of the screening efficiency of epiretinal membrane using confocal scanning laser ophthalmoscope imaging and color fundus camera in elderly people

摘要目的 比较共聚焦激光扫描检眼镜(cSLO)眼底成像与传统眼底彩色照相对老年人黄斑前膜(ERM)的检出结果.方法 行常规体检的退休职工184人363只眼纳入研究.其中,男性153人304只眼,女性31人59只眼.年龄47~92岁,平均年龄74.35岁.所有受检者均行传统眼底彩色照相、cSLO眼底成像及高分辨率光相干断层扫描(HD-OCT)检查.对比观察传统眼底彩色照相和cSLO眼底成像的图像质量评分以及两种检查设备对ERM检出与HD-OCT检出的阳性符合率.结果 363只眼中,HD-OCT检出ERM 122只眼,检出率为33.6%;传统眼底彩色照相检出ERM 33只眼,检出率为9.1%;cSLO眼底成像检出ERM 76只眼,检出率为20.9%.传统跟底彩色照相ERM检出与HD-OCT ERM检出的阳性符合率为27.0%;cSLO眼底成像ERM检出与HD-OCT ERM检出的阳性符合率为62.3%.cSLO眼底成像ERM检出与HD-OCT ERM检出的阳性符合率明显高于传统眼底彩色照相,差异有统计学意义(x2=30.81,P<0.001).结论 对于老年人群,cSLO眼底成像ERM检出率及其与HD-OCT ERM检出的阳性符合率均较传统眼底彩色照相更高.

更多

abstractsObjective To determine the positive results of confocal scanning laser ophthalmoscope (cSLO) based retinal imaging and traditional color fundus camera in screening epiretinal membrane (ERM) in elderly people.Methods A total of 184 retired staffs from certain company (363 eyes) were included in this study,153 were men (304 eyes) and 31 were women (59 eyes).The mean age was 74.35 years (range 47-92 years).All subjects were underwent fundus imaging using cSLO technology and traditional color fundus camera and Cirrus high definition optical coherence tomography (HD-OCT).The imaging quality of two technologies were analyzed and compared according to the evaluation standards.The positive accordance rate was used to compare between two modes fundus imaging (cSLO technology and traditional color fundus camera) and HD-OCT.Results In 363 eyes,the positive number of screening ERM using HD-OCT was 122 eyes (33.6%);the positive number of traditional color fundus camera was 33 eyes (9.1%);the positive number of cSLO imaging was 76 eyes (20.9 %).The HD-OCT positive accordance rate of screening ERM using traditional color fundus camera and cSLO technology were 27.0% vs.62.3%.The HD-OCT positive accordance rate of screening ERM using cSLO technology was significant higher than traditional color fundus camera (x2 =30.81,P < 0.001).Conclusion The HD-OCT positive accordance rate of screening ERM in elderly people was higher using cSLO technology than using traditional color fundus camera.

More
广告
  • 浏览150
  • 下载181
中华眼底病杂志

中华眼底病杂志

2016年32卷6期

615-618页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷