医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis

摘要Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography (DSCT) with sinogram affirmed iterative reconstruction (SAFIRE) for non-enhanced abdominal and pelvic scans. <br> Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans (protocol 1) [tube voltage of 120 kVp/pitch of 0.9/filtered back-projection (FBP) reconstruction] followed by high-pitch non-enhanced CT scans (protocol 2) (100 kVp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio (SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. <br> Results The total scan time of protocol 2 was significantly shorter than that of protocol 1 (1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs (liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214;pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785;spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128;kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1 (liver, 5.0±1.2 vs. 4.5±1.1, P<0.001;pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001;spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001;kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001;abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001;psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol&nbsp;1 (9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1 (4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions (97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1 (4.4±0.4 mSv vs. 7.3±2.4 mSv, P<0.001) and the mean dose reduction was 41.4%. <br> Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.

更多
广告
作者单位 Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences&Peking Union Medical College, Beijing 100730, China [1]
发布时间 2015-01-09(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览82
  • 下载4
中国医学科学杂志(英文版)

中国医学科学杂志(英文版)

2014年4期

214-220页

MEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷