脑瘤灌注CT不同层厚CBV与rCBV测量的可重复性研究

Reproducibility of perfusion CT derived CBV and rCBV measurements with different slice thickness in patients with brain neoplasms

摘要Objective: To assess inter-and intraobserver reproducibility for measuring perfusion CT derived cerebral blood volume(CBV)and relative cerebral blood volume(rCBV)with different slice thickness in patients with brain neoplasms.Methods: Three independent observers who were blinded to the histopathologic diagnosis performed perfusion derived CBV and rCBV measurements with 5 mm and 10 mm slice thickness in 52 patients with various cerebral neoplasms.The results of the measurements with different slice thickness were compared.Calculation of coefficient of variation(CV), and relative paired difference of the measurements were used to determine the levels of inter-and intraobserver reproducibility.Results: The differences of CBV and rCBV measurements between different slice thickness groups were statistically significant(P<0.05)respectively in observer 2, and were not significant in the other two observers(P>0.05).For the same slice thickness, both the difference of CBV and rCBV measurements among the three observers were not statistically significant.Interobserver CV and relative paired difference of the measurements with 10 mm slice thickness group were slightly lower than those of 5 mm slice thickness group.Interobserver CV and relative paired difference of CBV group were slightly lower than those of rCBV group.The intraobserver differences of CBV and rCBV in 10 mm slice thickness group were statistically significant for observer 2 respectively.No other intraobserver differences of measurements were statistically significant.CV and relative paired difference of intraobserver CBV and rCBV measurements for observer 2 were significantly higher than for the other two observers.Conclusion: High reproducibility of CBV and rCBV measurements was acquired with the two different slice thickness.Suitable training may be helpful to maintain a high level of consistency for measurements.

更多
广告
作者单位 Department of Radiology, Cangzhou Central Hospital, Cangzhou 061001, China [1] Operating Room of CLinic Service, Cangzhou Central Hospital, Cangzhou 061001, China [2]
分类号 R73
栏目名称
发布时间 2008-05-06
提交
  • 浏览360
  • 下载4
中德临床肿瘤学杂志(英文版)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷