SonoVue微泡粒径对新型绒癌细胞靶向造影剂结合特性的影响

Impact of the diameter of SonoVue microbubbles on binding characteristics of a new contrast agent targeted to choriocarcinoma cells in vitro

摘要Objective:To evaluate the impact of the diameter of SonoVue microbubbles on binding characteristics, including the adhesion rate and stability, of a new contrast agent targeted to choriocarcinoma cells (JARs) in vitro, in order to establish a foundation to explore targeted ultrasound imaging for localization of tumor cell antigens and increase the early diagnostic rate for tumors. Methods:The objects were divided into three groups:the large microbubble group (n=15), the middling microbubble group (n=15) and the tiny microbubble group (n=15). The rosette formation rate was counted. JARs were calcu-lated by flow cytometry (FCM). The targeted contrast agent was prepared by mixing SonoVue microbubbles of different diam-eter with rabbit anti-human chorionic gonadotrophin (HCG) antibody. The binding rates of the targeted contrast agent to JARs before and after PBS rinse were analyzed. Results:The binding rate was significantly lower in the large microbubble group [(61.7±1.8)%] than in the middling microbubble group [(82.6±4.5)%] and the tiny microbubble group [(91.3±5.8)%] (P< 0.05). The binding rates of different diameter microbubbles to JARs before and after PBS rinse were different. The middling microbubbles were the most stable ones, with the binding rate of (82.3±4.5)% and (80.4±3.9)% before and after PBS rinse (P > 0.05). The binding rates of the targeted microbubbles labeled with fluorescence to JARs were 68.6%, 81.3% and 89.3% in the large microbubble group, the middling microbubble group and the tiny microbubble group, respectively (P< 0.05). Conclu-sion:The binding capacity of the targeted SonoVue microbubbles to JARs is related to the diameter of the microbubble, which is determined by the shaking method before preparation. Modulating the diameter of SonoVue microbubbles may increase the binding rate and stability of targeted microbubbles to JARs, thus to improve the image of JARs.

更多
广告
分类号 R73(肿瘤学)
栏目名称
DOI 10.1007/s10330-009-0008-8
发布时间 2009-05-26(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览191
  • 下载0
中德临床肿瘤学杂志(英文版)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷