• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment

摘要Flattening filter-free (FFF) beams generated by medical linear particle accelerators (linacs) have recently been used in radiotherapy clinical practice. FFF beams have fundamental physical parameter differences with respect to standard flattening filter (FF) beams, such that the generally used dosimetric parameters and definitions are not always viable. This study investigates dosimetric parameters for use in the quality assurance of FFF beams generated by medical linacs in radiotherapy. The main characteristics of the photon beams are analyzed using specific data generated by a Varian TrueBeam linac having both FFF and FF beams of 6 and 10 MV (megavolt) energy, respectively. Definitions for dose profile parameters are suggested, starting from the renormalization of the FFF with respect to the corresponding FF beam. From this point, the flatness concept is translated into one of "un-flatness", and other definitions are proposed, maintaining a strict parallelism between FFF and FF parameter concepts. The quality controls used in establishing a quality assurance program when introducing FFF beams into the clinical environment are given, maintaining similarity to those used for standard FF beams, and recommendations for the introduction of FFF beams into clinical radiotherapy application for breast cancer patients are provided as an example for comparison between FFF and FF for dose distribution and coverage for a target volume. Although there are many advantages of using a FFF beam, especially for advanced radiotherapy techniques, there are a few limitations (e.g., using a relatively higher energy photon beam for stereotactic radiotherapy (SRT), limited speed of current multileaf collimators (MLCs), and off-axis distance-dependent modulation in intensitymodulated radiation therapy (IMRT)) as well as challenges (e.g., criteria for beam quality evaluation and penumbra, establishment of dosimetry methods, and consequences of photon target burn-up) that need to be addressed for establishing the FFF beam as a viable alternative to the FF beam.

更多
广告
作者单位 Al Galaa Oncology Center, Egypt [1] Clinical Oncology Department-Faculty of Medicine-Al Azhar University, Cairo, Egypt [2] National Center for Radiation Research and Technology-AEA, Egypt [3] Physics Department Women College for Arts Science and Education-Ain Sham University, Cairo,Egypt [4]
DOI 10.1007/s10330-016-0183-3
发布时间 2018-01-25
提交
  • 浏览46
  • 下载4
肿瘤学与转化医学(英文)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷