• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

A multi-provincial survey and analysis of radiation doses from pediatric CT in China

摘要Objective:To survey and analyze the radiation doses of pediatric CT in some provinces(autonomous region)or municipalities in China,and compare them with the data released by the relevant domestic and international organizations,so as to identify the current status of Chinese pediatric CT radiation doses.Methods:Radiation doses of pediatric CT were collected during August and December 2016 from 40 hospitals(including 18 children's hospitals)in 15 provinces,municipalities or autonomous regions across the China.The procedures of head CT,chest CT and abdomen CT were selected in these hospitals,and 10 patients in each group of0-<1 y,1-<5y,5-<10y and 10-<15 y were collected at random for every procedure.Weighted CT dose index(CTDIW),volumetric CT dose index(CTDIvol)and dose length product(DLP)were used as survey quantities.An independent sample Kruskal-Wallis rank sum test was performed for CTDI and DLP for each pro-cedure for different age groups,and pairwise comparisons were performed for intra-group data.The same sta-tistical method was also conducted for CTDI and DLP of the same procedure and age group in different provinces or municipalities.Results:The 75 th percentiles of the distribution of CTDI and DLP in different age groups of0-<1y,1-<5y,5-<10 y and 10-<15 y were as follows:36.5,43.4,49.1,51.1 mGy and 488,635,723,852 mGy.cm for head,6.1,6.4,6.8,9.6 mGy and 108,136,187,293 mGy.cm for chest,10.5,10.3,11.4,13.0 mGy and 251,284,353,523 mGy.cm for abdomen.The 50th percentiles of the distribution of the radiation doses for the same procedure varied with the ages(head,CTDIw:H=155.66,DLP:H=212.35,P<0.05;chest,CTDIvol:H=85.43,DLP:H=197.36,P<0.05;abdomen:H=62.29,DLP:H=173.22,P<0.05)and with lower dose at lower age.Radiation doses were close for head between 5-<10 y and 10-<15 y groups,for chest between 1-<5 y and 5-<10 y groups and between 5-<10 y and 10-<15 y groups,and for abdomen between 0-<1 y and 1-<5 y groups,with no statistically significant difference(the adjusted P>0.05).The dose levels of different provinces or municipalities in the same procedure and age group were not consistent,and the differences were statistically significant(P<0.05).The data were different from the domestic and international values of DRL.The 75th percentiles of CTDIW and DLP values of head CT were close to the data from Japan and UK(United Kingdom),higher than the data from Korea and EC(European Commission).The 75th percentiles of CTDI values of all age groups were lower than the values of Japan and UK,and larger than that of Korea and EC in chest CT and abdomen CT.Conclusions:The 75th percentile values of the distribution of the pediatric CT doses obtained from the survey were inconsistent with those released by the relevant national and international organizations.It is necessary to update the national DRLs for pediatric CT on the basis of the actual survey data.

更多
广告
作者 Tianliang Kang [1] Zongrui Zhang [1] Yongxian Zhang [1] Erdong Chen [2] Yantao Niu [1] 学术成果认领
作者单位 Beijing Tongren Hospital Capital Medical University,Beijing,100730,China [1] National Institute for Radiological Protection,Chinese Center for Disease Control and Prevention,Beijing,100088,China [2]
栏目名称 Original Articles
DOI 10.1016/j.radmp.2021.02.001
发布时间 2024-06-18
提交
  • 浏览2
  • 下载0
放射医学与防护(英文)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷