• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

HyperArc performance in radiotherapy and its correlations with number and volume of multiple brain metastases

摘要Objective:To assess the performance and advantages of HyperArc for radiotherapy of multiple brain metastases with dosimetric parameters with respect to coplanar volumetric modulated arc radiotherapy(c-VMAT),and characterize implicit correlations between tumor features and dosimetric parameters.Methods:This retrospective study involved 40 patients with multiple brain metastases(4-16 tumors,12.8-240.8 cm3)who received simultaneous radiotherapy at the Department of Radiation Oncology,Shenzhen People's Hospital from January 2019 to December 2022.Both HyperArc and c-VMAT plans were designed by the same and qualified physicist using the Eclipse system with Truebeam.A single isocenter and a 6 MV flattening filter-free(6FFF)photon beam were used for radiotherapy of multiple brain metastases in each plan.Dosimetric parameters of tumors and organs at risk(OARs)were compared between HyperArc and c-VMAT plans.Corre-lations between tumor features(number and volume)and dosimetric parameters were revealed and analyzed.Furthermore,monitor units(MUs)of both plan types were recorded to assess rays utilization and delivery efficiency.Results:Compared to c-VMAT plans,HyperArc plans achieved higher maximum dose(Dmax)(5.23%,t=7.87,P<0.01),but lower minimum dose(Dmin)(3.94%,t=-2.12,P=0.04)and mean dose(Dmean)(1.05%,t=-3.29,P<0.01)for planning gross tumor volumes(PGTVs).The conformity index(CI),homogeneity index(HI),gradient index(GI)and Rso%of PGTVs with HyperArc were better than those with c-VMAT,with the improve-ments of 20.78%,1.68%,19.83%and 36.20%,respectively(P<0.01).The dosimetric parameters of OARs were significantly improved in HyperArc plans compared to c-VMAT plans.Specifically,the Dmax and the Dmean to the brainstem decreased by 16.14%and 11.37%,respectively.The Dmax for eye_L decreased by 16.88%,for eye_R decreased by 11.67%,for optical nerve-L decreased by 12.56%,and for chiasm decreased by 18.12%.Few correlations were observed between the differences of CI/HI/GI/Rso%and the number of PGTVs between the two plan types.Whereas,regression analysis indicated that the differences of CI/GI/Rso%were negatively correlated with the volume of PGTVs,respectively.Moreover,although HyperArc plans reduced the MUs by 4.74%compared to c-VMAT,no significant difference was observed(P>0.05).Conclusions:This study demonstrates the promising performance of HyperArc for radiotherapy of multiple brain metastases,including better dose conformity for the tumors,more rapid dose drop and less dose spillage outside the tumors area,effective reduction of dose bridges among close tumors,and sparing OARs.It also reveals the correlations between the number or volume of tumors and dose parameters,which can help optimize the use of HyperArc and predict clinical benefits.

更多
广告
作者 Hongtao Chen [1] Zihuang Li [1] Guixiang Liao [1] Lijun Wang [1] Xiaonian Deng [1] Heli Zhong [1] 学术成果认领
作者单位 Department of Radiation Oncology,Shenzhen People's Hospital,The Second Clinical Medical College,Jinan University,The First Affiliated Hospital,Southern University of Science and Technology,Shenzhen,518020,China [1]
栏目名称 Original articles
DOI 10.1016/j.radmp.2024.05.004
发布时间 2024-07-17
提交
  • 浏览2
  • 下载0
放射医学与防护(英文)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷