医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Dosimetric performance of HyperArc and VMAT techniques using full or ipsilateral arcs for unilateral temporal lobe tumor radiotherapy

摘要Objective:To assess the dosimetric performance of HyperArc and volumetric modulated arc radiotherapy(VMAT)techniques,using either full or ipsilateral arcs,for the radiotherapy of unilateral temporal lobe tumor,in order to quantify and analyze differences among these planning approaches using various dosimetric parameters.Methods:This retrospective study reviewed 30 patients with unilateral temporal lobe tumors treated with radiotherapy in the Department of Radiation Oncology,Shenzhen People's Hospital from August 2020 to December 2023.Using the Eclipse treatment plan system with the Truebeam machine model,HyperArc and VMAT plans were designed with full or ipsilateral arcs,respectively Dosimetric parameters for the planning target volume(PTV)and organs at risk(OARs)were computed and analyzed.Additionally,the monitor units(MU)of four types of plans were calculated for consideration of rays utilization and delivery efficiency.Results:HyperArc demonstrated superior dosimetric performance for PTV and OARs compared to VMAT(P<0.05),with exceptions noted for the low dose volume(V5 Gy)of the healthy brain and mean dose of ipsilateral cochlea.Ipsilateral arcs and full arcs showed similar efficacy in sparing OARs adjacent to PTV.Furthermore,full arcs improved PTV conformity compared with ipsilateral arcs(P<0.05),while ipsilateral arcs reduced the dose to contralateral OARs,mean dose and the middle-to-low dose volume of the healthy brain(P<0.05).Regarding MU,HyperArc(full)plans exhibited the minimum values among the four plan types,with overall MU for HyperArc plans being less than those for VMAT.Conclusions:This study not only highlights the outstanding performance of the HyperArc technique with respect to VMAT but also underscores the advantages of employing ipsilateral arcs over full arcs in the radiotherapy of unilateral temporal lobe tumor.Additionally,the HyperArc technique demonstrated higher efficiency of ray utilization and delivery.The findings of this study can aid in selecting appropriate techniques and guiding arcs arrangements for the radiotherapy of unilateral temporal lobe tumor.

更多
广告
作者 Hongtao Chen [1] Lijun Wang [1] Zhuangling Li [1] Shihai Wu [1] Zihuang Li [1] 学术成果认领
作者单位 Department of Radiation Oncology,Shenzhen People's Hospital,Second Clinical Medical College,Jinan University,First Affiliated Hospital,Southern University of Science and Technology,Shenzhen 518020,China [1]
栏目名称
DOI 10.1016/j.radmp.2025.04.002
发布时间 2025-09-08(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览2
  • 下载0
放射医学与防护(英文)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷