• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

头颈部肿瘤两种放疗体位固定摆位误差分析

Analysis of setup errors using two immobilization techniques in the radiotherapy of head-and-neck cancer

摘要目的:应用千伏级锥形束CT(CBCT)对比分析头颈部肿瘤放疗中头枕+头颈肩面膜、真空气垫+头颈肩面膜两种体位固定技术的摆位误差。方法随机选取60例接受诊断及治疗的头颈部肿瘤患者(头枕+头颈肩面膜组29例、真空气垫+头颈肩面膜组31例),治疗过程中每周行1次CBCT扫描,将所获取的CBCT图像与计划CT图像进行配准,得到左右、上下、前后方向的摆位线性误差,采用独立t检验对比两组数据的差异性。结果头枕+头颈肩面膜组在左右、上下、前后方向的摆位线性误差分别为:(0.07±1.70)、(0.45±1.53)、(0.39±1.62) mm,真空气垫+头颈肩面膜组在左右、上下、前后方向的摆位线性误差分别为:(-0.05±1.39)、(0.13±1.37)、(0.08±1.25) mm。两组在左右方向上的摆位线性误差比较差异无统计学意义(t=0.729, P>0.05),在上下和前后方向上的差异有统计学意义(t=2.093、2.039, P均<0.05)。结论两种固定方式中头颈部肿瘤真空气垫+头颈肩面膜固定的患者摆位误差小,体位重复性好。

更多

abstractsObjective To analyze the setup errors of two immobilization techniques (pillow +head-and-neck shoulder mask and vacuum bag + head-and-neck shoulder mask)with KV- cone beam computed tomography ( CBCT ) for head-and-neck cancer radiotherapy . Methods Sixty head-and-neck cancer patients who diagnosed and treated in Panyu central hospital were randomly selected and divided into two groups(29 patients of pillow + head-and-neck shoulder mask group and 31 patients of vacuum bag + head-and-neck shoulder mask group). CBCT was weekly carried out before treatment delivery. Then, the CBCT images were matched with the planned CT images in order to get the setup errors in left-right, superior-inferior and anterior-posterior directions. Independent t-test was used to evaluate the differences. Results In the pillow+head-and-neck shoulder mask group, the average setup errors values in the left-right, superior-inferior and anterior-posterior directions were(0.07±1.70), (0.45±1.53), (0.39± 1.62) mm, respectively. Also in the vacuum bag+head-and-neck shoulder mask group, the average setup errors values were (-0.05 ±1.39), (0.13 ±1.37), (0.08 ±1.25) mm, respectively. And in the left -right direction, there was no statistically significant difference (t=0.729, P>0.05). While, in the superior-inferior and anterior-posterior directions, both of which had statistically significant difference(t=2.093 and 2.039, both P<0.05). Conclusion The vacuum bag+head-and-neck shoulder mask fixed technique was more accurate when compared to the pillow+head-and-neck shoulder mask fixation method, which has the smaller setup errors and the better position repeatability.

More
广告
  • 浏览365
  • 下载68
国际放射医学核医学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷