国产 68Ge- 68Ga发生器的制备及初步应用评价
Preparation and preliminary application evaluation of a domestic 68Ge- 68Ga generator
摘要目的:制备国产 68Ge- 68Ga发生器,通过与进口 68Ge- 68Ga发生器(德国ITG公司)进行对比,对其进行初步应用评价。 方法:制备 68Ge- 68Ga发生器,测定其淋洗后初始时间(0)、1、4、12 h的淋洗产物 68Ga 3+的放射性活度;与进口 68Ge- 68Ga发生器淋洗产物 68Ga 3+的γ能谱及 68Ga 3+在正常小鼠体内的分布情况进行对比;确定国产 68Ge- 68Ga发生器淋洗产物标记前列腺特异性膜抗原(PSMA)-11的最佳标记条件及产物的放射化学纯度;对比国产与进口 68Ge- 68Ga发生器淋洗产物标记的 68Ga-PSMA-11在22Rv1前列腺癌肿瘤模型小鼠体内的分布情况。计量资料的组间比较采用LSD法进行检验。 结果:国产 68Ge- 68Ga发生器在淋洗后初始时间(0)、1、4、12 h的淋洗产物 68Ga 3+的放射性活度分别为125.8、74.0、118.4、111.0 MBq。国产与进口 68Ge- 68Ga发生器淋洗产物 68Ga 3+的γ能谱高度一致,在正常小鼠体内的分布基本没有差异,均在心脏呈现放射性高摄取。国产 68Ge- 68Ga发生器淋洗产物标记PSMA-11的最佳标记条件是pH值4.5,85℃恒温反应15 min,得到的 68Ga-PSMA-11的放射化学纯度>95%。国产与进口 68Ge- 68Ga发生器淋洗产物标记的 68Ga-PSMA-11在22Rv1前列腺癌肿瘤模型小鼠体内的显像结果显示, 68Ga-PSMA-11均在肿瘤部位呈现高摄取,其余主要分布于肾脏和膀胱。国产 68Ge- 68Ga发生器淋洗产物标记的 68Ga-PSMA-11注射后30、60、90 min,肿瘤部位的放射性摄取值均低于进口 68Ge- 68Ga发生器[(3.60±0.14) %ID/g对(5.30±0.42) %ID/g、(3.40±0.12) %ID/g对(5.90±0.36) %ID/g、(2.90±0.28) %ID/g对(5.50±0.33) %ID/g],且差异均有统计学意义(LSD法,均 P<0.05)。 结论:国产 68Ge- 68Ga发生器淋洗产物 68Ga 3+及其标记的 68Ga-PSMA-11在正常小鼠和肿瘤模型小鼠体内的分布情况与进口 68Ge- 68Ga发生器无明显差异。
更多相关知识
abstractsObjective:To prepare a domestically produced 68Ge- 68Ga generator and compare it with an imported 68Ge- 68Ga generator (ITG Company, Germany) for preliminary application evaluation. Methods:A 68Ge- 68Ga generator was prepared, and the radioactivity of its elution product 68Ga 3+ was measured at the initial time (0) and 1, 4, and 12 h after elution. The γ-spectra of the elution product 68Ga 3+ and its distribution in normal mice were compared with those of an imported 68Ge- 68Ga generator. The optimal labeling conditions for prostate-specific membrane antigen (PSMA)-11 labeled by domestic 68Ge- 68Ga generator elution product and the radiochemical purity of the labeled product were determined, and the distribution of 68Ga-PSMA-11 labeled by domestic and imported 68Ge- 68Ga generator elution products in 22Rv1 prostate cancer tumor model mice was compared. The intergroup comparison of measurement data was conducted using the LSD method. Results:The radioactivity values of 68Ga 3+ in the elution product of the domestic 68Ge- 68Ga generator at the initial time (0), 1, 4, and 12 h after elution were 125.8, 74.0, 118.4, and 111.0 MBq, respectively. The γ-spectra of 68Ga 3+ eluted by domestic and imported 68Ge- 68Ga generators were highly consistent, and no difference was observed in the distribution of 68Ga 3+ in normal mice, and both showed high uptake of radioactivity in the heart. The optimal labeling conditions for PSMA-11 labeled by domestic 68Ge- 68Ga generator elution product were pH 4.5, reaction at 85 ℃ for 15 min, and the radiochemical purity of the product 68Ga-PSMA-11 was >95%. The imaging results of 68Ga-PSMA-11 labeled by domestic and imported generator elution products in 22Rv1 prostate cancer model mice showed high uptake of 68Ga-PSMA-11 at the tumor site, while the rest were mainly distributed in the kidneys and bladder. At 30, 60, and 90 min after injection, the radioactive uptake values of 68Ga-PSMA-11 labeled by the domestic 68Ge- 68Ga generator were lower than those of the imported 68Ge- 68Ga generator ((3.60±0.14) %ID/g vs. (5.30±0.42) %ID/g, (3.40±0.12) %ID/g vs. (5.90±0.36) %ID/g, (2.90±0.28) %ID/g vs. (5.50±0.33) %ID/g). The differences were statistically significant (LSD method, all P<0.05). Conclusion:No significant difference was observed in the distribution of 68Ga 3+ and its labeled 68Ga-PSMA-11 in normal mice and tumor model mice between the domestic 68Ge- 68Ga generator and the imported 68Ge- 68Ga generator.
More相关知识
- 浏览0
- 被引9
- 下载0

相似文献
- 中文期刊
- 外文期刊
- 学位论文
- 会议论文


换一批