肌电活动对Narcotrend和脑电双频谱指数监测右美托咪啶镇静深度的影响

Effects of electromyographic activity on the accuracy of Narcotrend and bispectral index during sedation with dexmedetomidine

摘要目的 探讨硬膜外阻滞期间,肌电活动(electromyographic avtivity,EMG)的变化对Narcotrend和脑电双频指数(bispectral index,BIS)监测右美托咪啶(dexmedetomidine,Dex)镇静深度准确性的影响. 方法 择期拟行硬膜外阻滞的患者16例,男9例、女7例,美国麻醉医师协会(ASA)分级Ⅰ~Ⅱ级,年龄18岁~60岁,体重51 kg~93 kg,体重指数19.2 kg/m2~27.8kg/m2.硬膜外阻滞效果确切后,经静脉持续输注浓度4 mg/L Dex负荷量0.5 μg/kg(输注15 min),继以0.4 μg·kg-1·h-1恒速泵入维持至术毕.每隔1 min记录Narcotrend指数(Narcotrend index,NTI)、BIS及EMG(信号及数据采集来自BIS监护仪),并采用警觉/镇静评分(the Observer's Assessment of Alterness/Sedation Scale,OAA/S)评估镇静深度. 结果 高EMG活动(EMG>50dB)时,BIS、NTI未随EMG增高而升高(r=-0.113,P=0.249;r=0.160,P=0.249).BIS及NTI值“虚高”,即BIS、NTI ≥85而OAA/S≤3分,分别发生在50%(8/16)和56 %(9/16)的患者中,此时BIS中位数(四分位数间距)87(86~91)与EMG 34(32~36);NTI 90(87~94)与EMG 41(37~48)均不存在相关关系(r=-0.046,P=0.855;r=0.090,P=0.732). 结论 硬膜外阻滞下Dex镇静期间,高EMG活动不引起BIS及NTI升高;BIS、NTI“虚高”与EMG活动增加无关,即Narcotrend及BIS对Dex镇静深度判断的准确性未受EMG增加的明显干扰.

更多

abstractsObjective To investigate the effects of electromyographic activity on the accuracy of Narcotrend and bispectral index (BIS) during sedation with dexmedetomidine (Dex) under epidural anesthesia.Methods Sixteen patients scheduled for epidural anesthesia,9 males and 7 females,ASA Ⅰ or Ⅱ,aged 18 y-60 y,weighing 51 kg-93 kg,BMI 19.2 kg/m2-27.8 kg/m2 were prospectively studied.After the induction of epidural anesthesia,a loading dose of Dex was administered at 0.5 μg/kg per 15 min,followed by a continuous infusion at 0.4 μg ·kg-1 ·h-1,BIS and Narcotrend were monitored simultaneously,both values and EMG which was indicated on the BIS platform were recorded every minute.Sedation was assessed using the Observer's Assessment of Alterness/Sedation Scale (OAA/S) as well.The correlation between Narcotrend index (NTI)/BIS and EMG was analyzed.Results As the EMG activities above 50 dB elevated,BIS and NTI values were not increased (r=0.113,P=0.249;r=0.160,P=0.249).The misleading high BIS/NTI ≥85 occurred among 8 (50% of all cases) and 9 (56% of all cases) patients,respectively,at OAA/S ≤3.While there was no correlation (r=-0.046,P=-0.855) between BIS M (QR)87 (86-91) and EMG 34 (32-36),and there was no correlation (r=0.090,P=0.732) between NTI 90 (87-94) and EMG 41 (37-48),either.Conclusions During sedation with Dex under epidural anesthesia,high EMG activities do not result in BIS/NTI value increases.Impractical high BIS/NTI values are not caused by EMG elevation.Under sedation with Dex,the Narcotrend and BIS monitor are comparatively reliable with regard to their insusceptibility to increased EMG activity.

More
广告
  • 浏览0
  • 下载0
国际麻醉学与复苏杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷