医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

CBCT用于测量GALL线的可重复性研究

A Research on the measurement reproducibility of gall line using CBCT

摘要目的:结合锥形束CT(cone-beam computed tomography, CBCT)影像和Dolphin软件转化头颅侧位片,研究Andrews要素Ⅱ目标前界线(goal anterior limit line, GALL)的可重复性。方法:选取57例患者CBCT影像导入Dolphin软件转化头颅侧位片,根据Andrews要素Ⅱ进行定点测量,得出临床前额平面与FALL线(forehead's anterior limit line)所成的角度及上颌中切牙FA(facial-axis point)点至GALL线的距离。由3名经软件测量培训的专业正畸医生执行。操作者分别测量2次,间隔1周。采用组内相关系数(ICC)检验同一操作者测量可重复性,以及不同操作者对同一指标测量结果的一致性。结果:同一操作者测量上颌中切牙FA点与GALL线距离(a)及临床前额平面与FALL线所成的角度(b),ICC检验结果表明每一位操作者对该测量方法的掌握度和可重复性好。不同操作者之间采用该测量方法测量a和b,ICC分别为0.965和0.912表明可靠性高且一致性好。结论:Andrews要素Ⅱ的GALL线测量,运用CBCT影像结合Dolphin软件转化头颅侧位片及相应的测量设计方法具有较好的一致性和可重复性,可应用于临床正畸。

更多

abstractsObjective:Combining with cone-beam computed tomography (CBCT) and the CBCT-generated cephalograms by Dolphin software to measure the reproducibility of the goal anterior limit line (GALL) in the Andrews Element Ⅱ.Methods:The CBCT-generated cephalograms by Dolphin software of 57 orthodontic patients were measured according to the method we designed by Andrews' element Ⅱ to acquire the acute angle formed between the clinical forehead's surface and the forehead's anterior limit line (FALL) and the distance between the facial-axis point (FA) points of maxillary central incisors to the GALL. All above operations were performed by three doctors who had received the training of software measurement and had orthodontic expertise. Each observer had repeated twice with the time interval of 1 week. The ICC of the measurement results were used to evaluate the reproducibility for intra-observer and the consistency of the same quantitative measurement results between different observers.Results:For the measurement results of the distance between the FA points of maxillary central incisors to the GALL (a) and the angle between clinical forehead's surface and FALL (b), the ICC test showed the measurement results by the same observer operating showed good reproducibility. As for the measurement results of the distance between a and b by the three observers, the ICC test results were 0.965 and 0.912, showing good reliability and consistency.Conclusions:The measuring method of the GALL in the Andrews' element Ⅱ has good consistency and reproducibility by combining CBCT image and Dolphin-generated cephalograms, and it could be used clinically.

More
广告
作者 张家榕 [1] 陈奕嘉 [2] 高文玲 [2] 朱双林 [2] 学术成果认领
作者单位 广州市妇女儿童医疗中心口腔正畸科 510623 [1] 中山大学光华口腔医学院·附属口腔医院口腔正畸科 510055 [2]
栏目名称
DOI 10.3760/cma.j.cn115797-20190910-21105
发布时间 2026-01-27(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览548
  • 下载10
中华口腔正畸学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷