医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Left ventricular morphological and functional adaptation in severe aortic stenosis after transcatheter aortic valve implantation

摘要Background Transcatheter aortic valve implantation (TAVI) has been confirmed to improve the prognosis of high-risk patients with severe aortic stenosis (AS),still little is known about changes in left ventricular (LV)morphology and function after TAVI beyond 12 months.This study evaluated the effect of TAVI on LV morpho-logical and functional adaptation in patients with severe AS 12 months after implantation.Methods AS patients with TAVI were selected from January 2018 to December 2020 in our hospital.Transthoracic echocardiography was performed before and 12 months after TAVI to determine LV morphology and LV function.Morphological parameters,such as left ventricular end-diastolic (LVDd) dimension,left ventricular end-systolic (LVDs) dimen-sion,interventricular septum thickness (IVST),posterior wall thicknesses (PWT),left ventricular mass (LVM),and left ventricular mass index (LVMI) were included.Left ventricular ejection fraction (LVEF) and Tissue Dop-pler imaging (TDI)-derived peak systolic myocardial velocity (S') were recorded to assess LV function.Results A total of 58 consecutive patients with severe AS who underwent TAVI were included.In all subjects,TAVI re-markably reduced peak transaortic velocity (4.6±0.6 m/s at baseline vs.2.0±0.5 m/s after TAVI,P<0.001) and mean transaortic gradient (51± 15.8 mmHg at baseline vs.5.3±3.6 mmHg after TAVI,P<0.001),and improved aortic valve area (AVA) significantly (0.7±0.2 cm2 at baseline vs.1.8±0.4 cm2 after TAVI,P<0.001).IVST re-gressed from 14.1±8.2 mm to 12.5±3.1 mm and PWT from 13.3±7.1 mm to 10.8±2.9 mm (P<0.05).LV mass and LV mass index decreased from 316±98 g to 219±62 g (P<0.001) and from 182±46 g/m2 to 118±28 g/m2 (P<0.001),respectively.There was a statistically significant improvement in LV function (LVEF:50.6%±11.3% at baseline vs.65.1%±7.6% after TAVI;S':3.4±1.3 cm/s at baseline vs.4.5±1.4 cm/s after TAVI,P<0.05).Howev-er,LVDd (45.2±10.6 mm at baseline vs.49.1±5.5 mm after TAVI,P=0.235) and LVDs (30.4±12.3 mm at base-line vs.34.6±4.3 mm after TAVI,P=0.346) did not change remarkably.Conclusions Significant LV function improvement and LV hypertrophy regression were found in patients with severe AS 12 months after TAVI.These changes suggested that TAVI can reverse LV remodeling.

更多
广告
作者 MA Qing-yan [1] FU Ming [1] CHEN Ou-di [1] 学术成果认领
作者单位 Department of Noninvasive Cardiology,Guangdong Provincial Cardiovascular Institute,Guangdong Provincial People's Hospital,Guangdong Academy of Medical Sciences,Guangzhou 510180,Guangdong,China [1]
栏目名称
发布时间 2022-03-22(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览4
  • 下载0
岭南心血管病杂志(英文版)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷