医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Modified Maze lines plus pulmonary vein isolation created by radiofrequency catheter ablation on the atrial wall to treat atrial fibrillation in elderly

摘要Objective To evaluate the effect of modified Maze lines plus pulmonary vein (PV) isolation created by radiofrequency catheter ablation (RFCA) on atrial wall guided by a novel geometry mapping system in the treatment of elderly patients with paroxysmal atrial fibrillation (PAF). Methods After regular electrophysiological study, transseptal punctures were achieved twice with Swartz L1 and R1 sheaths. PV angiographies were conducted to evaluate their orifices and branches. A balloon electrode array catheter with 64 electrodes was put in the middle of the left atrium. Atrium geometry was constructed using Ensite 3000 Navx system. Two RFCA lesion loops and three lines (modified Maze) were created on left and right atrial walls. Each lesion point was ablated for 30 seconds with preset temperature 50 (ae) and energy 30W. The disappearance or 80% decrease of the amplitude of target atrial potential and 10 to 20(|), decrease of ablation impedance were used as an index of effective ablation. Results A total of 11 patients (7 male and 4 female, mean age, 68.7±5.1 years) were enrolled. PAF history was 7.9±4.5 years. PAF could not be prevented by mean 3.1±1.6 antiarrhythmic agents in 6.3±3.4 years. None of the patients had complications with structural heart disease or stroke. Left atrial diameter was 41.3±3.6 mm and LVEF was 59.2±3.7% on echocardiography. Two loops and three lines were completed with 67.8±13.1 (73-167) lesion points. Altogether 76-168 (89.4±15.3) lesion points were created in each patient. PAF could not be provoked by rapid burst pacing up to 600 beat per minute delivered from paroxysmal coronary sinus electrode pair.Complete PV electrical isolation was confirmed by three-dimensional activation mapping. Mean procedure time was 2.7±0.6 hours and fluoroscopy time was 17.8±9.4 minutes. Patients were discharged with oral aspirin and without antiarrhythmic agents. During follow up of 6.5±1.8 months, seven patients were PAF symptom free (63.6%). PAF attacks were decreased more than 70% in two patients (18.2%). PAF frequency did not change in another two patients (18.2%). Conclusions Ensite 3000 Navx guided modified Maze lines plus PV isolation on the atrial wall is safe and feasible in the elderly patients. It has the advantages of exact procedural endpoint, shorter X-ray exposure, fewer complications and satisfied long-term effect PAF control.

更多
广告
提交
  • 浏览89
  • 下载0
老年心脏病学杂志(英文版)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷