• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Characterization of focal liver lesions with SonoVue(R)-enhanced sonography: International multicenter-study in comparison to CT and MRI

摘要AIM: To evaluate in a multicenter study whether the sonographic characterization of focal liver lesions can be improved using SonoVue(R)-enhancement; and to compare this method with computed tomography (CT) and magnetic resonance imaging (MRI). METHODS: One hundred and thirty four patients with one focal liver lesion detected in baseline ultrasound (US) were examined with conventional US, contrastenhanced US ( n = 134), contrast-enhanced CT ( n = 115) and/or dynamic contrast-enhanced MRI ( n = 70). The lesions were classified as malignant, benign or indeterminate and the type of lesion was determined.The final diagnosis based on the combined information of all imaging examinations, clinical information and histology ( n = 32) was used. Comparisons were made to see whether the addition of contrast-enhanced US led to the improvement of the characterization of doubtful focal liver lesions. RESULTS: In comparison with unenhanced US, SonoVue(r) markedly improves sensitivity and specificity for the characterization (malignant/benign) of focal liver lesions. In comparison with CT and/or dynamic MRI, SonoVue(r) -enhanced sonography applied for characterization of focal liver lesions was 30.2% more sensitive in the recognition of malignancy and 16.1% more specific in the exclusion of malignancy and overall 22.9% more accurate. In the subgroup with confirmative histology available ( n = 30), sensitivity was 95.5% (CEUS), 72.2% (CT) and 81.8% (MRI), and specificity was 75.0% (CEUS), 37.5% (CT) and 42.9% (MRI). The sensitivity and specificity of CEUS for the identification of focal nodular hyperplasia (FNH) and hemangiomas was 100% and 87%, resulting in an accuracy of 94.5%. CONCLUSION: SonoVue(r)-enhanced sonography emerges as the most sensitive, most specific and thus most accurate imaging modality for the characterization of focal liver lesions.

更多
广告
分类号 R5
栏目名称 ORIGINAL ARTICLES
DOI 10.3748/wjg.15.3748
发布时间 2009-09-28
提交
  • 浏览93
  • 下载1
世界胃肠病学杂志(英文版)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷