层流手术室术中无菌器械的有效时限

Effective time of sterile equipments used in laminar flow operating room

摘要目的 探讨层流手术室术中手术器械的安全使用时段.方法 选择手术时间持续8h或以上的Ⅰ类手术10例,对术前空气,术前及术中4,6,8h的手术器械以及手术人员的手进行采样,采样标本进行细菌培养.结果 术前空气、术中手术人员的手及手术器械均无细菌生长,合格率为100%.结论 在达到100级层流条件的手术室,同一台无菌手术的术中器械可以安全使用8h.

更多

abstractsObjective To investigate the safe time of sterile equipments used in laminar flow operating room.Methods In ten operations ( Class Ⅰ ) which last 8 or more hours,we sampled preoperative air,surgery equipments 4 h,6 h,8 h pre and intra-operatively,and surgical personnel' s hands for bacterial culture.Results There was no growth of bacteria in the sampling of preoperative air,surgical personnel's hands and surgical instruments during operation,pass rate was 100%.Conclusions The sterile equipments used in the same operation could be used safely for 8 hours in operating room where the condition of Level 100 laminar flow reached.