肝门部血流对胆管腔内射频消融的影响

Effects of portal blood flow on intraductal radiofrequency ablation

摘要目的 观察活体时肝门部胆管腔内射频消融能否形成凝固区,探讨肝门部血流对凝固区大小的影响.方法 从6头健康家猪选取14个肝门部胆管靶点,分为非肝门阻断组和肝门阻断组,每组7个胆管靶点.将单极电极针13 mm裸露部分置入胆管腔内,输出功率5W,消融时间4min.病理检查胆管和邻近肝组织改变.结果 两组剖面均可见半椭圆形灰白色凝固区,凝固区周围有明显的暗红色环状带.光镜下凝固区胆管黏膜层和黏膜下层变性、坏死;肝组织变性;暗红色环状带为肝组织出血.非肝门阻断组和肝门阻断组凝固区平均长轴直径分别为(13.29±1.38)mm、(13.29±1.11)mm,差异无统计学意义(t=0.000,P>0.05);凝固区平均短轴直径分别为(3.14±1.07)mm、(4.57±0.98)mm,差异有统计学意义(t=2.611,P<0.05).结论 活体时肝门部胆管腔内射频消融可形成典型的射频消融区.肝门部血流影响凝固区短轴直径,不影响凝固区长轴直径.

更多

abstractsObjective To observe whether coagulation zones can be produced by intraductal radiofrequency ablation (RFA) in vivo and investigate the effect of portal blood flow on the sizes of coagulation zones. Methods Fourteen bile duct targets in hepatic hilar from 6 swines were equally divided into non-Pringle manoeuvre group and Pringle manoeuvre group. A 13mm segment of non-insulated mono-electrode was inserted into the bile duct, then RFA was performed under the condition of 5 W power output for 4 minutes. The pathological changes of bile duct and adjacent hepatic tissues were observed. Results Semi-oval offwhite coagulation zones in the sections were observed in both groups, with obvious dark-red rims around them. Necrosis and denaturation of mucosal and submucosal layers of bile duct and denaturation of adjacent hepatic tissue in coagulation zones were observed under optical microscope. The dark-red rims revealed hepatic hemorrhage. The mean long axial diameter of coagulation zones in the non-Pringle manoeuvre group and Pringle manoeuvre group was (13.29±1.38)mm and (13.29±1.1 1)mm, respectively, with no statistical difference (t=0.000, P>0.05). The mean short axial diameter of coagulation zones in the non-Pringle manoeuvre group and Pringle manoeuvre group was (3.14±1.07)mm and (4.57±0.98)mm, respectively, with statistical difference (t=2.611, P<0.05). Conclusions Intraductal RFA can produce a typical ablation zone. The portal blood flow affects the short axial diameter of coagulation zone but does not affect the long axial diameter.

More
广告
  • 浏览212
  • 下载20
中华消化外科杂志

中华消化外科杂志

2008年7卷3期

203-205页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷