医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

IOL-Master测量硅油填充眼屈光结果分析

Evaluation of ocular refraction in silicone oil temponade eyes by the IOL-Master system

摘要目的 评价IOL-Master测量硅油填充眼屈光度数的准确性并分析不同因素与术后屈光误差的关系.方法 29例(29眼)硅油填充眼行硅油取出联合人工晶状体(IOL)植入术,术前用IOL-Master进行IOL测量.根据不同病因、硅油放置时间、眼轴、术后并发症等因素进行分类,研究术后视力恢复情况及测量误差产生的原因.结果 术后视力较术前均有不同程度的提高,屈光度数的平均预测误差为0.329±0.846 (-1.5~-2.0D),眼轴长度(P>0.05)、病因 [裂孔源性(t=0.478,P=0.637)、黄斑裂孔(t=0.135,P=0.895)]、是否近视(t=0.435,P=0.667)与术后产生的屈光误差均无相关性,硅油存留时间<1年者术后矫正视力恢复好.结论 硅油填充眼患者采用硅油取出联合IOL植入术对视力有一定提高,IOL-Master测量硅油填充眼IOL度数是相对准确、安全、方便的方式.

更多

abstractsBackground The combination procedure of the removal of silicon oil and cataract extraction+intraocular lens (IOL) implantation is the main method of treating cataract in silicone oil tamponade eye.However,the conventional measuring method of the IOL power is limiting in eyes with silicone oil tamponade.The IOL-Master system is confirmed to be an ideal non-contact optical measuring instrument in vivo.Objective The aim of this study is to measure the preoperative IOL power,evaluate the accuracy of biometry with the IOL-Master system and compare the relationship between different factors and refractive error.Methods IOL power was measured in 29 silicone oil tamponade eyes of 29 patients prior to the silicone oil removal combining IOL implantation with the IOL-Master system according to different factors such as placement time,axis oculi,complications and so on.The reasons of visual acuity recovery and measurement error were discussed.Results Postoperative visual acuity was improved in all of the patients.The average predictive refractive error was 0.329±0.846 (-1.5--2D).Classified factors for the cause of disease for axis oculi included rhegmatogenous retinal detachment (RRD)(t=0.478,P=0.637),macular hole(t=0.135,P=0.895),myopia(t=0.435,P=0.667)and oil-placed time (good for less than 1 year).These factors showed an indirect relationship with errors.Conclusion Silicone oil removal combined with IOL implantation can improve visual acuity.The IOL-Master biometry is accurate,safe and convenient in measuring the IOL power in silicon oil temponade eye,but future research should be performed to decrease the measuring error.

More
广告
栏目名称
DOI 10.3969/j.issn.1003-0808.2010.03.022
发布时间 2010-04-09(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览369
  • 下载66
眼科研究

眼科研究

2010年28卷3期

271-274页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷