Improving Dose Accuracy in Cancer Radiation Therapy Using Deformable Image Registration

摘要Objective To explore the differences in volume and doses to clinical target volumes (CTVs) and organs at risk (OARs) with and without adaptive treatment plans by using deformable image registration technology. Methods Ten patients with head and neck cancer were selected for this retrospective study. Each patient’s original treatment plan was generated using the Eclipse treatment planning system (Varian, Inc.). Verification CT scans were performed during the third week of treatment. The verification CT images were registered with the original CT images using the Eclipse rigid registration tool simulating daily patient treatment alignment. Then, deformable image registrations (Velocity, Inc.) were performed between the two CT image sets, and the CTVs and major OARs were transferred from the original CT images to the verification CT images. The original treatment plan was then copied into the verification CT image set to calculate the radiation dose reflecting the most recent anatomic changes. Verification plan doses were evaluated by a radiation oncologist, who determined whether an adaptive treatment plan was required. We compared the accumulated doses to CTVs and OARs between the original and adaptive plans, as well as between the adaptive and verification plans, to simulate the doses that would have been delivered if the adaptive plans were not used. All dosimetric data were extracted using the Eclipse Application Programming Interface tool, which was developed in house to access the Eclipse database. Results Body contours were different after 3 weeks of treatment. Mean volumes of all CTVs were reduced (P≤0.04), and the volumes of left and right parotid glands decreased (P≤0.004). There were no significant differences in the volumes of brainstem and oral cavity (P≥0.14) between the original and verification CT scans. The spinal cord had a mean 8.7% decrease in volume (P=0.04). Mean doses of CTVs were all decreased (P≤0.04), whereas the mean doses of the right parotid and oral cavity were increased (P=0.03). Conclusion Verification CT scans and adaptive planning are required during the course of proton therapy for patients with head and neck cancer to identify anatomic and dosimetric changes and to ensure adequate doses to target volumes and safe doses to normal tissues. Our results indicate that deformable image registration can serve as an essential tool for current proton treatment.

更多
广告
作者单位 Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA [1] Biomedical Engineering Consultants, LLC, Houston, Texas, USA [2] Convivia, 0akland, California, USA [3]
DOI 10.3969/j.issn.1674-1633.2016.11.002
发布时间 2016-12-02(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览17
  • 下载1
中国医疗设备

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷