医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

近视眼角膜前表面点扩散函数的斯特列尔比特征分析

Analysis of strehl ratio characteristics of the anterior corneal surface of myopic eyes

摘要目的 探讨不同瞳孔直径下近视眼角膜前表面总像差的斯特列尔比(SR)与总高阶像差SR的正常值及其与调制传递函数(MTF)的关系.方法 横断面研究.应用Sirius 3D角膜地形图仪对200例(400眼)进行角膜前表面总像差的SR和总高阶像差的SR检查.采用单因素方差分析比较角膜前表面总像差的SR和总高阶像差的SR分别在不同瞳孔直径下(3.0、5.0、6.0、7.0 mm)的差异.Pearson相关分析研究二者分别与对应的均方根值(RMS)的相关性,以及总像差SR与对应的MTF值的之间的相关性.结果 在不同瞳孔直径下(3.0、5.0、6.0、7.0mm)角膜前表面总像差100' SR值为(0.46±0.13) ~ (0.14±0.03);总高阶像差100'SR值为(0.69±0.15)~(0.17±0.04);角膜前表面总像差200'SR值为(0.45±0.13)~(0.16±0.04);总高阶像差200' SR值为(0.70±0.15) ~ (0.20±0.05),各组均逐渐变小;角膜前表面总像差SR值和总高阶像差SR值与对应的RMS值之间均存在负相关关系.当瞳孔直径小时,总像差SR值与MTF值的高频区相关性较高;而当瞳孔直径大时,总像差SR值与MTF值的低频区相关性较高.结论 近视眼角膜前表面总像差SR值和总高阶像差SR值与瞳孔直径呈负相关,并且SR值与RMS值及MTF值之间均存在一定的相关性.

更多

abstractsObjective To study the normal strehl ratio (SR) values of total aberrations and the SR values of total higher order aberrations on the anterior corneal surface of myopic eyes with different pupil diameters; to study the relationship between SR values and the modulation transfer function (MTF).Methods It was a cross-sectional study.The SR values of total aberrations and total higher order aberrations of the anterior corneal surfaces of 200 people (400 eyes) were examined with a SIRIUS 3D topography system.One-way ANOVA aualysis was used to compare the SR values of total aberrations and total higher order aberrations of the anterior corneal surface for different pupil diameters (3.0,5.0,6.0,7.0 mm).A Pearson correlation analysis was used to study the relationship between the two types of SR values and the corresponding root mean square (RMS) values; and the relationship between SR values of the total aberrations and corresponding MTF values.Results The results for different pupil diameters (3.0,5.0,6.0,7.0 mm) of the anterior corneal surface were as follows:the SR value of total aberrations 100' (0.46±0.13)-(0.14±0.03); the SR value of total higher order aberrations 100' (0.69±0.15)-(0.17±0.04); the SR value of total aberrations 200' (0.45±0.13)-(0.16±0.04); and the SR value of total higher-order aberrations 200' (0.70±0.15)-(0.20±0.05).The SR values of each group decreased with an increase in pupil diameter.The SR values of total aberrations and total higher-order aberrations on the anterior corneal surface were negatively correlated with the corresponding RMS values.When the pupil diameter was small,the SR value of total aberrations was more closely related to the higher frequency region of the MTF.When the pupil diameter was large,the SR value of total aberrations was more closely related to the lower frequency region of the MTF.Conclusion The SR values of total aberrations and total higher-order aberrations on the anterior corneal surface in myopic eyes are negatively correlated with pupil diameter.There is a certain correlation between SR values and the corresponding RMS and MTF values.

More
广告
作者 陈妍鹏 [1] 郑艳珍 [1] 邱岩 [2] 翟国光 [2] 张燕 [2] 李耀宇 [2] 学术成果认领
作者单位 100700 北京军区总医院眼科;030001 太原,山西医科大学 [1] 100700,北京军区总医院眼科 [2]
栏目名称
DOI 10.3760/cma.j.issn.1674-845X.2012.09.006
发布时间 2013-01-21(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览337
  • 下载72
中华眼视光学与视觉科学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷