Mutual comparative analysis:a new topography-guided custom ablation protocol referencing subjective refraction to modify corneal topographic data

摘要Background:Several planning algorithms have been developed for topography-guided custom ablation treatment(T-CAT),but each has its own deficiencies.The purpose of this study is to demonstrate the potential of a novel mutual comparative analysis(MCA)informed by manifest refraction and corneal topographic data and the patient's subjective perception in correcting ametropia.Methods:This retrospective review included patients with significant preoperative differences in the power or axis of astigmatism according to the manifest refraction and corneal topographic data(power>0.75 D and/or axis>10°).T-CAT planning was designed using MCA.Follow-ups were conducted for at least 6 months.Results:Seventy-nine patients(121 eyes)were included.The mean preoperative deviation in the astigmatic power and axis were 0.72±0.43 D and 20.18±23.68°,respectively.The average oculus residual astigmatism(ORA)was 0.81±0.32 D(range:0.08-1.66 D).Six months postoperatively,the mean spherical equivalent refraction was 0.04±0.42 D,and the mean cylinder was-0.27±0.24 D.The mean efficacy and safety indices were 1.10 and 1.15,respectively.The uncorrected distance visual acuity in 92%of the eyes was the same or better than the corrected distance visual acuity.The angle of error was±5° in 61%of eyes and±15° in 84%of eyes.Residual astigmatism was≤0.5 D in 91%of eyes.Optical quality and photopic contrast sensitivity did not change significantly(P>0.05),and the scotopic contrast sensitivity decreased at 3,6,and 12 cpd(P<0.05).The vertical coma and horizontal coma of the anterior corneal surface significantly decreased postoperatively but increased during follow-up.Conclusions:The MCA was demonstrated safety,efficacy,accuracy,predictability,and stability and can be used as a complementary and feasible method for T-CAT.

更多
广告
作者 Kaiwei Cao [1] Lina Liu [2] Tao Zhang [2] Ting Liu [3] Ji Bai [2] 学术成果认领
作者单位 77120 unit of People's Liberation Army(PLA),No.1441 FengJu Ring Road,Jinniu District,Chengdu 610081,China [1] Chongqing vision institute,No.77 Changjiang 2 Road,Yuzhong District,Chongqing 400042,China [2] Department of Ophthalmology,Daping Hospital and the Research Institute of Surgery of the Army Medical University of PLA,No.10 Changjiangzhii Road,Yuzhong District,Chongqing 400042,China [3]
发布时间 2022-10-08(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览1
  • 下载0
眼视光学杂志(英文版)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷