• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Development and validation of an HPLC-UV method for analysis of methylphenidate hydrochloride and loxapine succinate in an activated carbon disposal system

摘要Unused medications have the possibility of being abused, causing serious harm to individuals who were not prescribed the drug. The Food and Drug Administration (FDA) recommends the proper disposal of unused prescribed medications to maintain safety and prevent environmental hazards. However, many of the current disposal techniques do not properly address safety. A drug disposal pouch containing granular activated carbon offers a unique disposal method to deactivate residual or expiredmedication in a convenient, effective, and safe manner. A robust and validated method for methylphenidate hydrochloride and loxapine succinate was developed using high-performance liquid chromatography (HPLC) and the deactivation efficiency of the disposal system was tested. Methylphenidate hydrochloride was analyzed on a C18 analytical column (250mm × 4.60mm, 100?) using acetonitrile-water (0.05% (v/v) trifluoroacetic acid) as the mobile phase at a flow rate of 1.0mL/min with a run time of 15min and retention time of 7.8min. Loxapine succinate was separated on a C8100? (250 mm × 4.6 mm, 5 μm) column maintained at 25 °C using a flow rate of 1.0mL/min. The run time was 10min and the retention time of the drug was around 4.6min.Mobile phase was composed of acetonitrile and water (0.3% triethylamine) at pH 3.0 as 40:60 (v/v). Reference standard solutions (100 μg/mL) for both drugs were prepared by dissolving in mobile phases. These methods provide good linearity (R2 = 0.999) over the range of 5–100 μg/mL for methylphenidate hydrochloride and 0.1–100 μg/mL for loxapine succinate. The assay methods were successfully applied to study the deactivation of these drugs.

更多
广告
作者单位 Department of Pharmaceutical Sciences, Mercer University, Atlanta, GA 30341, USA [1] Verde Environmental Technologies, 12900 Whitewater Drive, Minnetonka, MN 55343, USA [2]
栏目名称 Original Research Article
发布时间 2018-12-14
基金项目
The current research project was funded by Verde Technologies (Minnetonka, MN, USA) as an SBIR Phase Ⅱ contract from the National Institute on Drug Abuse (NIDA). Title: In-Home Deactivation System for Psychoactive Drugs Contract no HHSN271201400068C NIDA Reference no. N44DA-14-4420
提交
  • 浏览23
  • 下载4
药物分析学报(英文)

药物分析学报(英文)

2018年8卷6期

349-356页

SCIMEDLINECSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷