医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Dynamic enhanced multi-slice spiral CT in evaluation of blood flow patterns of solitary pulmonary nodules with enhancement

摘要Objective To investigate the methods of dynamic enhanced multi-slice spiral CT in evaluation of blood flow patterns of solitary pulmonary nodules (SPNs) with enhancement. Methods Seventy eight patients with SPNs (≤4 cm) with strong enhancement underwent dynamic multi-slice spiral CT (Marconi Mx8000) scan before and after contrast enhancement by injecting contrast material with a rate of 4 mL/s. For the 40 patients in protocol one, one scan was obtained every 2 seconds during 15-45 and 75- 105 seconds after injection, while for the 38 patients in protocol two, one scan was obtained every 2 seconds during 11-41 and 71-101 seconds. For all the patients, one scan was obtained every 30 seconds during 2 9 minutes. The section thickness was 2.5 mm for lesions ≤3 cm and 5 mm for lesions >3 cm. Standard algorithm was used in the image reconstruction. Precontrast and postcontrast attenuation on every scan was recorded. The perfusion,peak height, ratio of peak height of the SPN to that of the aorta and mean transit time were calculated. Results The peak height, perfusion, ratio of peak height of the SPN to that of the aorta and mean transit time in malignant SPNs were 34. 85 Hu±10.87 Hu, 30. 37 ml/(min· 100 g)±11. 14 ml/(min · 100 g), 13. 78%±3.96%, 14.19 s±6.19 s respectively in protocol one, while those in protocol two were 36.62 Hu±10.75 Hu,30.01 ml/(min · 100 g)±8.10 ml/(min · 100 g), 14.70 %±4.71%, 13.91 s±4.82 s respectively. No statistically significant differences were found between the peak height (t = 0. 673, P = 0. 503), perfusion (t =0.152, P=0.880), ratio of peak height of the SPN to that of the aorta (t 0.861, P 0.393) and mean transit time (t= 0. 199, P=0. 843) in malignant SPNs measured in protocol one and those measured in protocol two. All mean transit time in protocol two (36/36) were obtained, but only part of them (25/32) were ob tained in protocol one. Conclusion Dynamic enhanced multi-slice spiral CT is a non-invasive method for quantitative evaluation of blood flow patterns of SPNs with enhancement and scans beginning at 11 seconds after in jection of contrast material is suggested.

更多
广告
  • 浏览100
  • 下载4
中国肺癌杂志

中国肺癌杂志

2004年7卷6期

520-525页

MEDLINEISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷