• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Effect of Accessory Retention Forms on the Bond Strength of Resin-bonded Fixed Partial Dentures:a 3D Finite Element Study

摘要Interface debonding between prostheses and abutments was the most frequent failure mode of resin-bonded fixed partials dentures (RBFPDs) in clinic. The purpose of this study was to investigate the effect of accessory retention forms on the bond strength of RBFPDs. Three types of 3D finite element models were constructed. The model of posterior metal plate RBFPD with spoon-shaped occlusal rest seats served as the control. The remaining two types of models based on the control added the retention form design of the pin hole and axial groove respectively. The axial or buccolingual load of 150 N was applied on the prosthesis, first premolar and first molar respectively. The maximum principal stresses of the adhesive layer in different models were calculated. Under the load of the same magnitude, the stress due to the buccolingual load was significantly higher than that due to the axial load in the adhesive layer. The proximal shoulder, occlusal rest seats wall and the proximal margin adjacent to the shoulder were the high risk region where the adhesive layer damaged easily. Compared with the control model, the pin and groove models could slightly decrease the stress in the adhesive layer after the axial loading, while the stress in the adhesive layer drastically decreased after horizontal loading and reduced by 22% and 31%respectively. These results indicate that the horizontal occlusal force has a more serious harm to the debonding of RBFPDs. In addition, the accessory retention forms (e.g. pin and axial groove retention forms) can decrease the stress level in the adhesive layer, which are conducive to increase the load-bearing capacity of RBFPDs.

更多
广告
作者单位 Key Lab for Boimechanics and Mechanobiology of Education Ministry, School of Biological and Medical Engineering, Beihang University, Beijing 100083, China [1]
分类号 R783.3
栏目名称 Research papers
发布时间 2017-06-27
提交
  • 浏览14
  • 下载0
中国生物医学工程学报(英文版)

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷