• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Assessment of cardiac function and synchronicity in subjects with isolated bundle branch block using Doppler imaging

摘要Background Using tissue Doppler imaging and conventional echocardiographic technique, we examined the cardiac function and synchronicity in individuals with isolated right bundle branch block (RBBB) or left bundle branch block (LBBB) and assessed the relationship between QRS duration and synchronicity.Methods Subjects with isolated RBBB (n=20), LBBB (n=10) and normal controls (n=20) were studied with conventional echocardiography and tissue Doppler imaging. The difference between aortic and pulmonary preejection intervals was defined as interventricular delay. Parameters in septum and lateral wall were measured using tissue Doppler imaging, including peak sustained systolic velocity (SM), peak early (EM) and late (AM)diastolic velocities as well as time to peak velocities (Ts, TE and TA).Results Subjects with LBBB had lower SM and longer Ts than did the RBBB and control groups (P<0.05,P<0.001 respectively). A significant difference was observed in EM, being the lowest in the LBBB and the highest in the control group (P<0.05). Moreover, TE was longer in the LBBB group compared with the other two groups (P<0.001). Both AM and TA were similar among three groups (P>0.05). In the bundle branch block groups, one ventricle lagged about 40 ms behind the other. A significant correlation was found between interventricular delay and QRS duration (r =0.713, P<0.001).Conclusions Cardiac ventricles were not well synchronized with one ventricle lagging about 40 ms behind the other in subjects with LBBB or RBBB, even though only LBBB group showed barely perceptible, impaired cardiac function. In addition, QRS duration and cardiac asynchronicity were positively correlated.

更多
广告
作者单位 Centre of Arrhythmia Diagnosis and Treatment, Fuwai Hospital and Cardiovascular Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China [1] Department of Echocardiography, Fuwai Hospital and Cardiovascular Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China [2]
分类号 R5
栏目名称
发布时间 2006-06-26
提交
  • 浏览134
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2006年119卷10期

795-800页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷