医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Circulatory responses to nasotracheal intubation: comparison of GlideScope(R) videolaryngoscope and Macintosh direct laryngoscope

摘要Background The GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over theMacintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but no study has compared the circulatory responses to nasotracheal intubation (NTI) using the two devices. This prospective randomized clinical study was designed to determine whether there was a clinically relevant difference between the circulatory responses to NTI with the GSVL and the MDL.Methods Seventy-six adult patients were randomly allocated equally to the GSVL group and the MDL group. After induction of anesthesia, NTI was performed. Non-invasive blood pressure (BP) and heart rate (HR) were recorded before induction (baseline values) and immediately before intubation (post-induction values), at intubation and every minute for a further five minutes. During the observation, times required to reach the maximum values of systolic BP (SBP) and HR, times required for recovery of SBP and HR to postinduction values and incidence of SBP and HR percent changes>30% of baseline values were also noted. The product of HR and systolic BP, I.e. Rate pressure product (RPP), and the areas under SBP and HR vs. Time curves (AUCSBP and AUCHR) were calculated.Results The NTI with the GSVL resulted in significant increases in BP, HR and RPP compared to postinduction values, but these circulatory changes did not exceed baseline values. BPs at all measuring points, AUCSBP, maximum values of BP and incidence of SBP percent increase>30% of baseline value during the observation did not differ significantly between groups. However, HR and RPP at intubation and their maximum values, AUCHR and incidence of HR percent increase > 30% of baseline value were significantly higher in the MDL group than in the GSVL group. -times required for recovery of SBP and HR to postinduction values were significantly longer in the MDL group than in the GSVL group.Conclusions The pressor response to NTI with the GSVL and the MDL was similar, but the tachycardiac response to NTI was lesser and of a shorter duration when using a GSVL than when using an MDL.

更多
广告
分类号 R5(内科学)
栏目名称
发布时间 2008-08-21(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览106
  • 下载16
中华医学杂志(英文版)

中华医学杂志(英文版)

2008年20卷14期

1290-1296页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷