Evaluation of neointimal coverage of overlapping sirolimuseluting stents by optical coherence tomography

摘要Background Although overlapping sirolimus-eluting stents are often used in long lesions during percutaneous coronary intervention, it was not clear how intimal hyperplasia at the overlapping segments compares with that of single-layer sirolimus-eluting stents.Methods Optical coherence tomography (OCT) examinations were performed on 22 patients in whom overlapping sirolimus-eluting stents (SESs) were implanted. OCT images were analyzed off-line after the procedure. Still frames were selected and classified, and the length of overlap, lumen loss, and average neointimal thickness on the strut were measured. The stent strut was classified into well-apposed to vessel wall with apparent neointimal coverage (type A), well-apposed to vessel wall without neointimal coverage (type B), malapposed to the vessel wall without neointimal coverage (type C), and strut located at a major side branch (type D).Results There was no statistically significant difference between strut coverage types within overlapping and non-overlapping segments, but a greater percentage of type C struts were observed within the overlapping segments (5.2% vs 1.4%, P >0.05). Neither neointimal thickness ((175.0±59.9) um vs (168.3±90.2) pm, P=0.715) nor lumen loss ((1.61±0.55) mm2 vs (1.48±0.37) mm2, P=0.397) was statistically different between the two segments. One patient was diagnosed with suspected in-stent thrombosis at 6 months. Although no specific characteristics of thrombosis were seen on the OCT images, a greater number of malapposed struts without neointima coverage were observed.Conclusions About 90% struts were completely covered by neointimal proliferation at 12 months follow-up, and the thicknesses of neointima on overlapping and non-overlapping segments were similar. Most of type C struts at the overlapping segments were found on the inside layer stents. Delayed antiplatelet therapy was beneficial for the patients with incompletely covered struts.

更多
广告
分类号 R5
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.2009.06.015
发布时间 2009-04-24
提交
  • 浏览135
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2009年122卷6期

670-674页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷