• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Accuracy and repeatability of direct ciliary sulcus diameter measurements by full-scale 50-megahertz ultrasound biomicroscopy

摘要Background Phakic intraocular lens (pIOL) implantation has been a popular means for the treatment of high ametropia. Measurements of ciliary sulcus diameter is important for pIOL size determining. But till now, no perfect system can directly measure it. The present study was to evaluate the accuracy, repeatability and reproducibility of direct sulcus diameter measurements obtained by a full-scale 50-megahertz (MHz) ultrasound biomicroscopy (UBM).Methods A fresh cadaver human eye with a scale marker inserted through the posterior chamber plane from 3 o'clock to 9 o'clock meridian and 30 randomly selected eyes from 30 normal subjects were scanned by full-scale 50-MHz UBM in horizontal meridional scan plane. The distance between the scales and the whole length of the marker inside the cadaver eye were measured by the same observer using the "built-in" measurement tools and the indicating error of instrument was calculated. Reproducibility of the measurement was evaluated in 30 eyes by 2 operators using Blander and Altman plot test. Repeatability was evaluated from 10 successive eyes randomly selected from the 30 eyes by one operator.Results On a scale of 1 mm, the greatest indicating error was 40 μm; the mean largest indicating error of 1 mm scale from the 10 images was (26±14) μm; on a scale of 11 mm, the greatest indicating error was 70 μo; the error rate was 0.64%. The mean length of the needle inside the eye of the 10 images was 11.05 mm, with the mean indicating error of 47 μm, the average error rate was 0.43%. For ciliary sulcus diameter measurements in vivo, the coefficient of variation was 0.38%; the coefficients of repeatability for intra-observer and inter-observer measurements were 1.99% and 2.55%, respectively. The limits of agreement for intra-observer and inter-observer measurement were-0.41 mm to 0.48 mm and -0.59 mm to 0.58 ram, respectively.Conclusion The full-scale 50-MHz UBM can be a high accuracy and good repeatability means for direct measuring the ciliary sulcus diameter and useful for size determining of posterior chamber pIOL.

更多
广告
分类号 R5
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.2009.08.015
发布时间 2009-05-19
提交
  • 浏览180
  • 下载17
中华医学杂志(英文版)

中华医学杂志(英文版)

2009年122卷8期

955-959页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷