• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Comparison of the incidence of late stent thrombosis after implantation of different drug-eluting stents in the real world coronary heart disease patients: three-year follow-up results

摘要Background Late stent thrombosis (LST) is still concerned by interventions cardiologists in daily clinical practice. This study aimed to compare the incidence of LST after implantation of different drug-eluting stents (DES) in coronary heart disease (CHD) patients in the real world.Methods From December 2001 to February 2009, a total of 11 875 consecutive CHD patients undergone DES implantation were enrolled in this single-center registery study. Patients with acute ST-segment elevation myocardial infarction, mixed DES implantation, restenosis lesions, and patients who could not take dual antiplatlet medication and those who were contraindicated for coronary interventional treatment were excluded. All patients were treated with completed dual antiplatelet medications for at least 9 months after DES deployment. The follow-up was completed by outpatient visits, letter correspondence, phone calls and coronary angiography. Definite LST was diagnosed auording to the Academic Research Consortium (ARC) definition.Results Cypher or Cypher Select stents were implanted in 4104 cases, Taxus or Taxus Liberty stents in 2271 cases and Firebird stents (Chinese rapamycin-eluting stents) in 5500 cases. One-year follow-up was completed in 9693 patients, including 3346 cases with Cypher or Cypher Select stents, 1529 cases with Taxus or Taxus Liberty stents and 4818 cases with Firebird stents. Two- and three-year follow-up results were obtained in 7133 and 4353 patients, respectively, including 2410 and 1760 cases with Cypher or Cypher Select stents, 1285 and 900 cases with Taxus or Taxus Liberty stents as well as 3438 and 1693 cases with Firebird stents. One-year follow-up results showed that the incidence of LST was 1.08% in patients with Cypher or Cypher Select stents, 1.24% in those with Taxus or Taxus Liberty stents and 0.71% in those with Firebird stents; there was no significant difference between those with Cypher or Cypher Select and Firebird stents, but there was significant difference between those with Taxus or Taxus Liberty and Firebird stents (P=0.044). The incidence of LST at the 2- and 3-year follow-up was 1.33% and 1.70% in those with Cypher or Cypher Select stents, 1.40% and 1.70% in those with Taxus or Taxus Liberty stents, and 0.83% and 0.95% in those with Firebird stents, respectively. There were no significant differences among the three groups.Conclusions This study indicates that first-generation DES are acceptable to treat complex coronary lesions, and there is no significant difference of LST for three different DES.

更多
广告
分类号 R5
栏目名称
DOI 10.3760/cma.j.issn.0366-6999.2010.07.003
发布时间 2010-06-02
提交
  • 浏览139
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2010年123卷7期

778-781页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷