Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation

摘要Background The complicated anatomy of the cervical spine and the variation among pedicles reduces the accuracy and increases the risk of neurovascular complications associated with screw implantation in this region. In this study, we compared the accuracy of cervical (C2-C7) pedicle screw fixation assisted by X-ray fluoroscopy, computed tomography (CT)-based navigation, or intraoperative three-dimensional (3D) C-arm navigation.Methods This prospective cohort study was performed in 82 consecutive patients who underwent cervical pedicle screw fixation. The accuracy of screw insertion was assessed by postoperative CT scan with 3D reconstruction. The accuracy of screw insertion was assessed as: excellent (screw completely within pedicle); acceptable (≤ 1 mm screw outside pedicle cortex); poor (>1 mm screw outside pedicle cortex).Results A total of 145 screws were inserted in 24 patients who underwent C-arm fluoroscopy. Of these, 96 screws (66.2%) were excellent, 37 (25.5%) were acceptable, and 12 (8.3%) were poor. One hundred and fifty-nine screws were inserted in 29 patients in the CT-based navigation group. Among these, 141 (88.7%) were excellent, 14 (8.8%) were acceptable, and 4 (2.5%) were poor. A total of 140 screws were inserted in 29 patients in the intraoperative 3D C-arm navigation group, of which 127 (90.7%) were excellent, and 13 (9.3%) were acceptable. No severe or permanent neurovascular complications associated with screw insertion were observed in any patient.Conclusione CT-based and intraoperative 3D C-arm navigation were similarly accurate, and were both significantly more accurate than C-arm fluoroscopy for guiding cervical pedicle screw fixation. They were able to accurately guide the angle and depth of screw placement using visual 3D images. These two techniques are therefore preferable for high-risk cervical pedicle screw fixation. The ease and convenience of intraoperative 3D C-arm navigation suggests that it may replace virtual-fluoroscopy and CT-based navigation systems in future clinical applications.

更多
广告
分类号 R5
DOI 10.3760/cma.j.issn.0366-6999.2010.21.008
发布时间 2010-12-13
提交
  • 浏览235
  • 下载8
中华医学杂志(英文版)

中华医学杂志(英文版)

2010年123卷21期

2995-2998页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷