Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade Ⅲ partial articular-sided rotator cuff tears

摘要Background For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade Ⅲ partial articular-sided rotator cuff tears.Methods In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of .≤45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data.Results Gap formation for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair for the first cycle ((1.74±0.38) mm vs. (2.86±0.46) mm, respectively) and the last cycle ((3.77±0.45) mm vs. (5.89±0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair. Also, it had a higher mean ultimate tensile load and stiffness.Conclusions For grade Ⅲ partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.

更多
广告
分类号 R5
DOI 10.3760/cma.j.issn.0366-6999.2010.21.018
发布时间 2010-12-13
提交
  • 浏览118
  • 下载0
中华医学杂志(英文版)

中华医学杂志(英文版)

2010年123卷21期

3049-3054页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷