医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Study of differential proteins in lung adenocarcinoma using laser capture microdissection combined with liquid chip-mass spectrometry technology

摘要Background In recent years the proportion of lung adenocarcinoma (adCA) which occurs in lung cancer patients has increased. Using laser capture microdissection (LCM) combined with liquid chip-mass spectrometry technology, we aimed to screen lung cancer biomarkers by studying the proteins in the tissues of adCA.Methods We used LCM and magnetic bead based weak cation exchange (MB-WCX) to separate and purify the homogeneous adCA cells and normal calls from six cases of fresh adCA and matched normal lung tissues. The proteins were analyzed and identified by matrix assisted laser desorption/ionization time-of-fight mass spectrometry (MALDI-OF-MS). We screened for the best pattern using a radial basic function neural network algorithm.Results About 2.895x106 and 1.584x106 cells were satisfactorily obtained by LCM from six cases of fresh lung adCA and matched normal lung tissues, respectively. The homogeneities of cell population were estimated to be over 95% as determined by microscopic visualization. Comparing the differentially expressed proteins between the lung adCA and the matched normal lung group, 221 and 239 protein peaks, respectively, were found in the mass-to-charge ration (M/Z)between 800 Da and 10 000 Da. According to t test, the expression of two protein peaks at 7521.5 M/Z and 5079.3 M/Z had the largest difference between tissues. They were more weakly expressed in the lung adCA compared to the matched normal group. The two protein peaks could accurately separate the lung adCA from the matched normal lung group by the sample distribution chart. A discriminatory pattern which can separate the lung adCA from the matched normal lung tissue consisting of three proteins at 3358.1 M/Z, 5079.3 M/Z and 7521.5 M/Z was established by a radial basic function neural network algorithm with a sensitivity of 100% and a specificity of 100%.Conclusions Differential proteins in lung adCA were screened using LCM combined with liquid chip-mass spectrometry technology, and a biomarker model was established. It is possible that this technology is going to become a powerful tool in screening and early diagnosis of lung adCA.

更多
广告
分类号 R5(内科学)
DOI 10.3760/cma.j.issn.0366-6999.2010.22.026
发布时间 2010-12-15(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览212
  • 下载8
中华医学杂志(英文版)

中华医学杂志(英文版)

2010年123卷22期

3309-3313页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷