• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Pure alumina bearings with cementless stems versus sandwich bearings with cemented stems in total hip arthroplasty

摘要Background Ceramic bearing surfaces have been introduced to prevent osteolysis after total hip arthroplasty (THA),but little is known about the difference in clinical and radiological results between pure alumina and sandwich alumina bearings.The purpose of this study was to analyze the results obtained with third-generation alumina-on-alumina THA with two different designs both in liner and femoral stem fixation after a minimum follow-up of 4.2 years.Methods The results of 195 primary alumina-on-alumina THAs in 167 patients were evaluated.The procedures were performed between January 1998 and October 2006.Three patients died and 11 patients were lost to follow-up,leaving a total of 153 patients (181 hips) available for study.In the 88 group A patients,107 hips were implanted using pure alumina bearings with cementless femoral stems.These patients were followed for (6.84±1.49) years.In the 65 group B patients,74 hips were implanted using sandwich alumina ceramic bearings with cemented femoral stems.These patients had a follow-up period of (7.73±1.60) years.Patients in both groups were evaluated clinically and radiographically.Results One ceramic liner fracture occurred in group A and five took place in group B (P <0.05),four of them revised for liner fracture.In each group,one acetabular shell migration happened without liner breakage and two hips developed deep infections,and all these six hips received revisions.Nine femoral components loosened in group B,with seven undergoing revisions.Kaplan-Meier survivorship at 5 years for revision of any component for any reason in group A was 96.26% compared to 90.54% in group B (P <0.05).Better function was determined in group A (average Harris hip scores:92.13±2.85) than in group B (average Harris hip scores:86.03±4.21) and the difference was significant (P <0.05).Squeaking was not recorded in either group.Conclusions The sandwich design of the acetabular bearings can not reduce the migration rate in ceramic bearings but increase the liner fracture rate compared to pure ceramic liners.The high loosening rate in fluted and taped designed cemented stems with sandwich liners warrant caution to their use.

更多
广告
作者单位 Department of Orthopaedic Surgery, Second Affiliated Hospital,College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China [1]
分类号 R3
栏目名称 ORIGINAL ARTICLES
DOI 10.3760/cma.j.issn.0366-6999.2012.02.015
发布时间 2012-04-20
提交
  • 浏览230
  • 下载4
中华医学杂志(英文版)

中华医学杂志(英文版)

2012年125卷2期

244-248页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷