摘要Background Cervical disc arthroplasty is an alternative surgery to standard cervical decompression and fusion for disc degeneration.Different types of cervical disc prosthesis are used in China.The aim of this study was to evaluate the radiographic outcomes of cervical arthroplasty using the ProDisc-C prosthesis.Methods Radiographic evaluation,including static and dynamic flexion-extension lateral images,was performed at baseline and at final follow-up.Results Twenty six patients who had single-level ProDisc-C arthroplasty were followed up for a mean period of 63 months (56-76 months).The range of motion at the operated level was 9.3°±3.7° at baseline and 7.3°±3.5° at final follow-up,with a significant difference (P <0.05).Seventeen of 26 levels (65.4%) developed heterotopic ossification:three were classified as grade Ⅱ,13 were classified as grade Ⅲ,and 1 as grade Ⅳ,according to McAfee's classification.Forty nine adjacent segments were evaluated by lateral Ⅹ-ray and 18 (36.7%) segments developed adjacent segment degenerations.Conclusions ProDisc-C arthroplasty had acceptable radiographic results at 5-year follow-up.The range of motion was preserved.However,more than 60% of the patients developed heterotopic ossification.
更多相关知识
- 浏览137
- 被引5
- 下载12

相似文献
- 中文期刊
- 外文期刊
- 学位论文
- 会议论文