医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Application of a three-dimensional microsurgical video system for a rat femoral vessel anastomosis

摘要Background The operating microscopes have been applied to modern surgery for nearly a century.However,generations of microsurgeons have to flex their necks and fix their eyes on the eyepieces of a microscope continually that leads to physical and mental fatigue during a long operation.Stereoscopic three-dimensional (3D) media provides more ergonomic working environment,subsequently,resulting better performance in tasks and more accurate judgment.In this study,an alternative method of magnification was analyzed using a three-dimensional microsurgical video system and compared with the traditional method under microscopy to evaluate the availability and feasibility of a 3D microsurgical video system for microvascular anastomosis.Methods Forty Sprague-Dawley rats were randomly divided into four groups with each of 10.In 20 rats,10 femoral artery anastomoses with a conventional microscope (arterial microscope group) were compared with that of 10 femoral artery anastomoses with a 3D microsurgical video system (arterial 3D group).For the other 20 rats,10 femoral vein anastomoses using a conventional microscope (venous microscope group) were compared with that of 10 femoral vein anastomoses using a 3D microsurgical video system (venous 3D group).The arterial and venous microscope groups were considered to be the control groups.The arterial and venous 3D groups were the experimental groups.The examined criteria were as follows:anastomotic time,patency right after the procedure and 10 days later,number of sutures,vessel caliber,and pathological features.Results There were no differences between the operating equipment with respect to vessel caliber,anastomotic time,patency rate,number of sutures,and pathological changes in either the small arteries or veins.The average arterial anastomotic time of the arterial microscope group and arterial 3D group was 34.21 and 33.87 minutes,respectively (P >0.05).The average venous anastomotic time of the venous microscope group and venous 3D group was 29.95 and 31.50 minutes,respectively (P >0.05).Conclusions A small vessel anastomosis can be performed successfully with the help of a 3D display system.Although the vascular anastomotic time did not demonstrate a significant difference between the groups,the 3D microsurgical video system offers another option to improve the working environment for surgeons.Further development of our 3D monitoring system should focus on a higher resolution and better flexibility.

更多
广告
提交
  • 浏览77
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2014年127卷2期

348-352页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷