• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

摘要Background:The goal of total knee arthroplasty (TKA) is to restore knee kinematics.Knee prosthesis design plays a very important role in successful restoration.Here,kinematics models of normal and prosthetic knees were created and validated using previously published data.Methods:Computed tomography and magnetic resonance imaging scans of a healthy,anticorrosive female cadaver were used to establish a model of the entire lower limbs,including the femur,tibia,patella,fibula,distal femur cartilage,and medial and lateral menisci,as well as the anterior cruciate,posterior cruciate,medial collateral,and lateral collateral ligaments.The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis,which was then validated by comparison with a previous study.The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion.Results:Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study,suggesting that this model can be used for further analyses.The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient,or insufficiently aggressive,"rollback" compared with the lateral femur of the normal knee.In addition,a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis.Conclusions:There were still several differences between the kinematics of the PS knee prosthesis and a normal knee,suggesting room for improving the design of the PS knee prosthesis.The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

更多
广告
作者单位 Department of Orthopedics, Beijing DCN Orthopaedic Hospital, Beijing 100143, China [1] Department of Orthopedics, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100020, China [2] Department of Biomechanics, Naton Institute of Medical Technology, Beijing 100094, China [3]
栏目名称 Original Articles
DOI 10.4103/0366-6999.149205
发布时间 2015-02-13
基金项目
a grant of Beijing Municipal Science and Technology Commission
提交
  • 浏览30
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2015年128卷2期

216-221页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷