医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images

摘要Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA).This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee.Methods: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method.In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation.TSG cases were treated with the conventional method.Outcomes were obtained from the postoperative image examination and short-term follow-up.Results: Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG.The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively.The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG.Statistically significant differences were found between GPG and TSG in all measurements.Conclusions: A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images.This allows for shorter operative times and better postoperative alignment than the traditional surgery.Application of the digital guide plate may also result in better short-term outcomes.

更多
广告
作者单位 Department of Orthopedics, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi 530021, China [1] Department of Orthopedics, Guizhou Provincial People's Hospital, Guiyang, Guizhou 550002, China [2]
栏目名称
DOI 10.4103/0366-6999.176082
发布时间 2016-03-22(万方平台首次上网日期,不代表论文的发表时间)
提交
  • 浏览45
  • 下载12
中华医学杂志(英文版)

中华医学杂志(英文版)

2016年129卷4期

386-391页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷