Oral contrast agents lead to underestimation of dose calculation in volumetric-modulated arc therapy planning for pelvic irradiation

Oral contrast agents lead to underestimation of dose calculation in volumetric-modulated arc therapy planning for pelvic irradiation

摘要Background::The effects of oral contrast agents (OCAs) on dosimetry have not been studied in detail. Therefore, this study aimed to examine the influence of OCAs on dose calculation in volumetric-modulated arc therapy plans for rectal cancer.Methods::From 2008 to 2016, computed tomography (CT) images were obtained from 33 rectal cancer patients administered OCA with or without intravenous contrast agent (ICA) and 14 patients who received no contrast agent. CT numbers of organs at risk were recorded and converted to electronic densities. Volumetric-modulated arc therapy plans were designed before and after the original densities were replaced with non-enhanced densities. Doses to the planned target volume (PTV) and organs at risk were compared between the plans.Results::OCA significantly increased the mean and maximum densities of the bowels, while the effects of ICA on these parameters depended on the blood supply of the organs. With OCA, the actual doses for PTV were significantly higher than planned and doses to the bowel increased significantly although moderately. However, the increase in the volume receiving a high-range doses was substantial (the absolute change of intestine volume receiving ≥52 Gy: 1.46 [0.05-3.99, cubic centimeter range: -6.74 to 128.12], the absolute change of colon volume receiving ≥50 Gy: 0.34 [0.01-1.53 cc, range: -0.08 to 3.80 cc]. Dose changes due to ICA were insignificant. Pearson correlation showed that dose changes were significantly correlated with a high intestinal volume within or near the PTV ( ρ > 0.5, P < 0.05) and with the density of enhanced intestine ( ρ > 0.3, P < 0.05). Conclusions::Contrast agents applied in simulation cause underestimation of doses in actual treatment. The overdose due to ICA was slight, while that due to OCA was moderate. The bowel volume receiving ≥50Gy was dramatically increased when OCA within the bowel was absent. Physicians should be aware of these issues if the original plan is barely within clinical tolerance or if a considerable volume of enhanced intestine is within or near the PTV.

更多

abstractsBackground::The effects of oral contrast agents (OCAs) on dosimetry have not been studied in detail. Therefore, this study aimed to examine the influence of OCAs on dose calculation in volumetric-modulated arc therapy plans for rectal cancer.Methods::From 2008 to 2016, computed tomography (CT) images were obtained from 33 rectal cancer patients administered OCA with or without intravenous contrast agent (ICA) and 14 patients who received no contrast agent. CT numbers of organs at risk were recorded and converted to electronic densities. Volumetric-modulated arc therapy plans were designed before and after the original densities were replaced with non-enhanced densities. Doses to the planned target volume (PTV) and organs at risk were compared between the plans.Results::OCA significantly increased the mean and maximum densities of the bowels, while the effects of ICA on these parameters depended on the blood supply of the organs. With OCA, the actual doses for PTV were significantly higher than planned and doses to the bowel increased significantly although moderately. However, the increase in the volume receiving a high-range doses was substantial (the absolute change of intestine volume receiving ≥52 Gy: 1.46 [0.05-3.99, cubic centimeter range: -6.74 to 128.12], the absolute change of colon volume receiving ≥50 Gy: 0.34 [0.01-1.53 cc, range: -0.08 to 3.80 cc]. Dose changes due to ICA were insignificant. Pearson correlation showed that dose changes were significantly correlated with a high intestinal volume within or near the PTV ( ρ > 0.5, P < 0.05) and with the density of enhanced intestine ( ρ > 0.3, P < 0.05). Conclusions::Contrast agents applied in simulation cause underestimation of doses in actual treatment. The overdose due to ICA was slight, while that due to OCA was moderate. The bowel volume receiving ≥50Gy was dramatically increased when OCA within the bowel was absent. Physicians should be aware of these issues if the original plan is barely within clinical tolerance or if a considerable volume of enhanced intestine is within or near the PTV.

More
广告
作者 Jing Hao [1] Tian Yuan [1] Tang Yu [1] Wang Shu-Lian [1] Jin Jing [1] Song Yong-Wen [1] Liu Yue-Ping [1] Fang Hui [1] Chen Bo [1] Qi Shu-Nan [1] Tang Yuan [1] Lu Ning-Ning [1] Yang Yong [1] Li Ning [1] Li Ye-Xiong [1] 学术成果认领
作者单位 Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China [1]
栏目名称 Original Article
DOI 10.1097/CM9.0000000000001025
发布时间 2025-02-25
基金项目
This work was supported by the grants from the National Key Projects of Research and Development of China the Beijing Municipal Science & Technology Commission of China This work was supported by the grants from the National Key Projects of Research and Development of China the Beijing Municipal Science & Technology Commission of China
  • 浏览96
  • 下载16
中华医学杂志英文版

中华医学杂志英文版

2020年133卷17期

2061-2070页

SCIMEDLINEISTICCSCDCABP

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷