低剂量CT扫描诊断肋骨骨折的临床应用

Clinical application of low-dose CT in patients with rib fractures

摘要目的 评价低剂量CT检查诊断肋骨骨折的可行性及图像质量.方法 25例胸部外伤行CT检查的患者,采用64层螺旋CT自动曝光控制技术,于吸气末屏气对整个胸廓以噪声指数(NI)11、21进行2次扫描,2次扫描的其他参数均保持一致.记录每次扫描的平均管电流、CT容积剂量指数(CTDIvol)和有效剂量(ED).由2名放射诊断医师埘每次扫描所见的肋骨骨折按Ⅰ、Ⅱ、Ⅲ度进行统计,以Wilcoxon配对符号秩和检验比较其差异;以5分制对图像诊断的接受率及主观噪声进行评价.采用Kappa-致性检验评价2名医师评定结果 的一致性.结果 NI为11时,平均CTDIvol、ED分别为(13.88±5.17)mGy、(8.14 4-3.21)mSv;NI为21时,分别为(3.91±1.57)mGy、(2.31±0.97)mSv.NI为21的辐射剂量较NI为11者下降了72%.NI为11的平均管电流为(195.88±69.33)mAs、NI为21的平均管电流为(54.56±21.54)mAs.NI为21时扫描能检出NI为11时扫描所发现的全部Ⅱ度、Ⅲ度骨折及绝大部分Ⅰ度骨折.NI为11时骨窗的图像诊断接受率评分及主观噪声评分2名医师分别为(4.9±0.2)、(4.6±0.5)分;NI为21时平均为(3.5±0.5)、(3.3±0.5)分.2名医师对肋骨骨折的检出、图像诊断接受率及主观噪声的评定结果 Kappa值分别为0.876、0.820和0.792(P值均<0.01).结论 NI为21的低剂量CT扫描能满足临床对肋骨骨折诊断的要求.

更多

abstractsObjective To evaluate images quality and diagnostic feasibility of low-dose CT in patients with traumatic rib fractures.Methods Twenty-five patients presented with thoracic iniury were underwent 64-slice spiral CT scanning in inspiration breath-hold technique.Two scan protocols were performed.In one scan protocol noise index(NI)is 11,and in another NI is 21,but the other scan parameters were no difference.The mean value of tube current,the volume CT dose index(CTDIvol),and effective dose(ED)were recorded.Image quality was scored by 2 experienced radiologists using the 5-points scale.The numbers and degrees of rib fractures were recorded.The data were tested by using the Wilcoxon signed rank sum test.The differences of the inter-observer were determined by Kappa statistics.Results The mean CTDIvol and ED in scan protocol with NI of 11 were(13.88±5.17)mGy and(8.14±3.21)mSv,and that with NI of 21 were(3.91±1.57)mGy and(2.31±0.97)mSv.Compared the scan with NI of 11.there was 72%intrinsie dose reduction in the scan with NI of 21.The mean value of tube current in scan with NI of 11 and 21 were(195.88±69.33)mAs and(54.56±21.54)mAs.AIl patients with 11 and Ⅲ degree and most patients with I degree rib fractures that identified by the scan with NT of 11 were detected by the scan with NI of 21.There were no statistical difference between two scaus with the Wilcoxon signed rank sum test.The diagnostic acceptability and image noise score in the scan with NI of 11 were 4.9±0.2 and 4.6±0.5.and that with NI=21 were 3.5±0.5 and 3.3±0.5.There was prefect concordante in the inter-observers in diagnostic acceptability on finding of rib fractures.diagnostic acceptability and image noise(Kappa=0.876,0.820,0.792,P<0.01)between two scan protocols.Conclusion Rib fractures can be diagnosed by the low-dose CT using the scan protocol with NI of 21.

More
广告
作者 葛虓俊 [1] 吴昊 [1] 滑炎卿 [1] 王鸣鹏 [1] 毛定飚 [1] 唐平 [1] 胡非 [1] 张国桢 [1] 学术成果认领
作者单位 上海复旦大学医学院附属上海华东医院放射科,200040 [1]
栏目名称
DOI 10.3760/cma.j.issn.1005-1201.2011.05.016
发布时间 2011-07-29(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览538
  • 下载568
中华放射学杂志

中华放射学杂志

2011年45卷5期

492-495页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷