医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

单方向背景抑制 MR 扩散加权成像与三维短时反转恢复快速自旋回波成像增强扫描显示臂丛神经的对比研究

Comparison of MR neurography of the brachial plexus with unidirectionally encoded diffusion-weighted imaging with background signal suppression and enhanced three dimensional short inversion time inversion recovery sampling perfection with application optimized contrasts using different flip angle evolutions

摘要目的:比较单方向背景抑制扩散加权成像( DWIBS)与三维短时反转恢复快速自旋回波成像(3D STIR SPACE)增强扫描2种方法显示臂丛神经的优势及不足。方法20名正常志愿者行臂丛神经单方向DWIBS与3D STIR SPACE增强扫描,原始图像经冠状面MIP重组,所得图像质量分别从臂丛神经各部分显示情况及背景抑制情况( I~IV分评分法)2方面进行评价。双侧臂丛神经锁骨上部分(脊神经C5~T1)20名受试者双侧共计200支,锁骨下部分20名受试者双侧共计40支。2种成像方法对臂丛神经的显示情况进行配对资料χ2检验;对背景抑制情况评分结果采用非参数Wilcoxon符号秩和检验进行比较。结果单方向DWIBS与3D STIR SPACE增强扫描2种方法中,双侧臂丛神经锁骨上部分(C5~T1)、锁骨下部分的显示率分别是84%(167/200)、33%(13/40)与99%(198/200)、95%(38/40),2种方法间比较差异均具有统计学意义(χ2值分别为28.18、31.15,P值均<0.01);单方向DWIBS扫描背景抑制评分Ⅰ~Ⅳ分的分别为0、0、4、16名,3D STIR SPACE增强扫描背景抑制评分Ⅰ~Ⅳ分的分别为15、4、1、0名,2者间差异具有统计学意义(Z=3.96,P<0.01),3D STIR SPACE增强扫描背景抑制评分明显优于单方向DWIBS。结论3D STIR SPACE增强扫描较单方向DWIBS可获得更好的臂丛神经图像质量,能显示臂丛神经全部走行。

更多

abstractsObjective To evaluate two different MRI techniques , enhanced 3D STIR SPACE and unidirectionally-encoded DWIBS MR Neurography in visualizing the brachial plexus.Methods Twenty healthy volunteers underwent MR scanning by the procedures of unidirectionally -encoded DWIBS and enhanced 3D STIR SPACE sequence of the brachial plexus.Original images were reconstructed with coronal maximum intensity projection ( MIP ).The image quality was assessed by comparing the visualization of various parts of the brachial plexus and the suppression ratio of image background.The degree of visualization was compared via χ2-test of paired data , and comparison of background suppression scores was performed using a nonparametric Wilcoxon signed rank sum test.Results The successful rate of visualizing the brachial plexus supraclavicular section ( C5-T1 ) was 84% ( 167/200 ) and 99% ( 198/200 ) , respectively, for the DWIBS and enhanced 3D STIR SPACE, and the rate for the infraclavicular section was 33%( 13/40 ) and 95% ( 38/40 ).The differences between these two techniques were statistically significant (χ2 value was 28.18 and 31.15 respectively, P <0.01).In all images, the scores of grade (Ⅰ-Ⅳ) of background suppression were 0, 0, 4 and 16 for unidirectionally-encoded DWIBS, respectively;while they were 15, 4, 1 and 0 for enhanced 3D STIR SPACE.There was significant difference between the two techniques ( Z =3.96,P <0.01).Conclusions High-quality MR neurography of the&nbsp;brachial plexus can be obtained using the enhanced 3D STIR SPACE sequence.It offers a complete anatomical coverage of the brachial plexus , and thus demonstrates a better capacity in depicting the anatomy of brachial plexus as compared with the unidirectionally-encoded DWIBS.

More
广告
  • 浏览767
  • 下载448
中华放射学杂志

中华放射学杂志

2014年5期

395-398页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷