医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

基于脚本的乳腺癌切线野机架角度设置

Script-based automated placement of gantry angles for tangential beams of breast cancer

摘要目的 通过脚本寻找乳腺癌保乳术后正向调强放疗计划(fIMRT)中最优的切线野机架角度,以降低危及器官的受量.方法 采用脚本对手动布置切线野的46例(左、右两侧病例分别为26和20例)已治疗的保乳术后正向调强放疗计划进行重新设计,脚本程序由Pinnacle3计划系统内置的脚本功能配合Python语言编写.脚本程序统计保乳术后放疗患者在不同切线野角度下患侧肺V20、健侧乳腺D1和心脏V10等剂量学指数,采用罚分函数计算不同机架角度下各个危及器官的罚分值,以选取最优的切线野角度.结果 对于26例左侧乳腺癌计划,手动和脚本设置切线野患侧肺V20分别为(18.2±3.4)%和(18.1±3.4)%(P>0.05),健侧乳腺D1分别为(249.2±88.4)和(230.4±80.2)cGy(t=2.27,P<0.05),心脏V10分别为(13.7±5.7)%和(13.1±5.7)%(t=2.82,P<0.05).对于20例右侧乳腺癌计划,患侧肺的V20分别为(19.8±3.8)%和(19.8±3.9)%(P>0.05),健侧乳腺D1分别为(340.0±286.2)和(298.0±239.7)cGy(t=2.53,P<0.05).结论 与手动相比,脚本能个性化、量化地评估切线野机架角度对乳腺癌危及器官受量的影响,更好地平衡各个危及器官间的受量,进一步提升计划质量.

更多

abstractsObjective To reduce the dose to organ at risk ( OAR) by script-based optimizing the gantry angles of tangential beams for forward-planned intensity-modulated breast radiotherapy ( fIMRT ) plans. Methods A total of 46 patients with breast cancer (26 in left and 20 in right) after conservative surgery who were treated with manually planned fIMRT were retrospectively re-planned using a script to place the tangential beams automatically. The script program was developed using Pinnacle3 scripting language as imbedded in the Pinnacle3 treatment planning system, and the Python scripting language. Dosimetric indices, including V20 of the ipsilateral lung, D1 of the contralateral breast and V10 of the heart were extracted by the script for plans of different gantry angles. Then the optimal tangential angles were selected by a penalty function. Results For the 26 left breast cancer cases, V20 of the ipsilateral lung for manual and script were (18.2 ±3.4)% and (18.1 ±3.4)%, respectively(P>0.05), while D1 of the contra-lateral breast(249. 2 ± 88. 4) cGy and (230. 4 ± 80. 2) cGy, respectively( t=2. 27, P<0. 05), V10 of the heart (13. 7 ± 5. 7)% and (13. 1 ± 5. 7)%(t=2. 82, P<0. 05). The V20 of the ipsilateral lung of the 20 right breast cancer cases were (19. 8 ± 3. 8)% and (19. 8 ± 3. 9)%, respectively(P>0. 05). The script plans achieved better V10 of the heart[(298. 0 ± 239. 7) cGy] than the manual plans[(340. 0 ± 286. 2) cGy] (t =2. 53, P <0. 05). Conclusions Compared with the manualmethod, the script can assess of the impact of tangential beam angles on the OAR dose, patient-specifically and quantitatively, hence make better trade-offs and improve the plan quality.

More
广告
  • 浏览212
  • 下载56
中华放射医学与防护杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new智医 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷