• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

肝癌碘油标记图像对锥形束CT图像配准方法及靶区外放的影响

Analysis of CBCT image registration methods and the planning target volume margins for liver cancers using lipiodol as a direct surrogate for target localization

摘要目的 分析碘油标记的肝癌图像对有无图像引导放疗(IGRT)中不同配准方法及靶区外放范围的影响.方法 5例经动脉灌注化疗栓塞(TACE)后放疗的肝癌患者,在医科达IGRT联合主动呼吸控制(ABC)系统下,每日治疗前用锥形束CT (CBCT)采集图像.根据靶区及邻近器官进行治疗计划CT图像和CBCT容积图像配准,记录左右、上下、前后方向偏移值(CBCT1),并校正摆位误差;纠正后再次CBCT扫描与CT图像配准(CBCT2);治疗结束后,再次CBCT扫描与CT图像配准(CBCT3).用SPSS软件计算CTV-PTV的外放边界,对CBCT1、CBCT2、CBCT3比较结果行配对t检验.结果 CBCT1和CBCT2及CBCT3在左右、上下、前后方向偏移值不同,分别为0.254、-0.612、0.314 cm和0.020、0.014、-0.064 cm及-0.004、0.042、-0.040 cm.CTV-PTV外放边界无IGRT时左右、上下、前后方向分别为0.96、0.96、0.83 cm,有IGRT时为0.67、0.68、0.58 cm.离线分析放疗过程中CBCT下碘油图像形态变化发现,即使在靶区(碘油)精确配准下,肝脏在上下方向、椎体在3个方向上仍有很大偏移值.结论 IGRT技术带来的CTV -PTV外放减小约3 mm.内靶区无标记物患者,CTV -PTV外放应将肿瘤上下方向误差及椎体误差考虑在内.配准时如果单纯以肝缘图像为参考配准点,图像配准将会有很大不确定性.

更多

abstractsObjective To analyze the transitional shifts between with different sets of cone-beam computed tomography (CBCT) and the planning CT for liver cancer patients,and calculate the margins from clinical target volume (CTV) to the planning target volume (PTV) with and without image guided radiotherapy (IGRT).Methods Five liver cancer patients received radiotherapy after transcatheter arterial chemoembolization (TACE).The first CBCT images (CBCT1) were obtained with Elekta CBCT plus active breathing control (ABC) system before treatment.The second CBCT images (CBCT2 ) were obtained after correcting the set-up errors and the third CBCT images ( CBCT3 ) were obtained after treatment.The CBCT images were registered and matched with the planning CT images using lipiodol as a direct surrogate for target localization.The PTV margins were calculated by comparing the shift between planning CT and CBCT according to formula M =2.5 ( Σ doctor2 + Σ set-up2 + Σ transter2 )1/2.Paired t-test was used to compare the differences between the results from CBCT1,CBCT2 and CBCT3. Results The average transition shifts in the left-right ( LR),superior-inferior (SI) and anterior-posterior (AP) directions were 0.254,-0.612,0.314 cm between planning CT and CBCT1 ;were 0.020,0.014,-0.064 cm between planning CT and CBCT2 ;and they were -0.004,0.042,-0.040 cm between planning CT and CBCT3.The PTV margins were LR 0.96 cm,SI 0.96 cm and AP 0.83 cm without IGRT,and LR 0.67 cm,SI 0.68 cm and AP 0.58 cm with IGRT.Conclusions The PTV margins can be reduced by 3 mm with IGRT for liver cancer using lipiodol as a direct surrogate for target localization.

More
广告
  • 浏览412
  • 下载89
中华放射肿瘤学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷