• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

自制定位装置对喉癌CT-MRI图像放疗靶区勾画影响

Application of a self-made positioning device in laryngeal CT-MRI image fusion

摘要目的 使用自制定位装置对喉癌患者进行CT-MRI图像融合的探索,分析图像融合的精度和融合后靶区勾画的变化.方法 选择10例喉癌患者使用自制定位装置固定体位进行CT、MRI图像采集,应用互信息+手动融合法将图像融合,通过测量两幅图像内、外标记点位置偏差和GTV交叠度(PCT-MRI)来评价图像融合精度.依据CT、MRI、CT-MRI图像勾画GTV的VCT、VMRI、VCT-MRI,计算VCT和VMRI重叠部分的体积VCT-MRI,单因素方差分析差异性.结果 3个外标记点x、y、z轴向上平均位置偏差分别为(0.996±0.222)、(1.146±0.291)、(1.368±0.298) mm (P=0.000);内部解剖标志点平均位置偏差分别为(0.476±0.151)、(0.561±0.083)、(0.724±0.125) mm (P=0.000);VCT VMRI、VCT-MRI分别为(26.355±7.876)、(33.556±7.407)cm3、(19.875±8.588) cm3(P=0.000);PCT-MRI为(73.7±9.8)%.结论 应用自制定位装置可提高CT、MRI图像采集时的体位一致性;CT-MRI图像可提供更多的信息增加靶区定义精确性.

更多

abstractsObjective To investigate the application of a self-made positioning device in CT-MRI image fusion in patients with laryngeal tumor,as well as the precision of image fusion and the changes in target volume delineation after fusion.Methods A total of 10 patients with laryngeal cancer were enrolled,and a self-made positioning device was used to collect CT and MRI images in a fixed position.These images were fused by mutual information combined with manual fusion.The precision of image fusion was assessed by the positional deviation of internal and external markers and degree of gross tumor volume (GTV) overlap (PCT-MRI) between CT and MRI images.GTV was contoured based on CT images (VCr),MRI images (VMRI),and fused images (VCT+MRI).The overlapped volume of VCT and VMRI(VCT-MRI) Was calculated,and the target volume was analyzed and compared.Results The positional deviations of three external markers in the three directions were 0.996±0.222 mm,1.146±0.291 mm,and 1.368±0.298 mm (P=0.000),respectively,while those of the internal markers were 0.476±0.151 mm,0.561±0.083 mm,and 0.724± 0.125 mm (P=0.000),respectively.VCT,VMRI,VCT+MRI,and VCT-MRI were 26.355±7.876 cm3,33.556± 7.407 cm3,40.036±7.627 cm3,19.875±8.588 cm3(P=0.000),respectively.PCT-MRI was 73.7%±9.8%.Conclusions The self-made positioning device can improve the consistency of position during the collection of CT and MRI images,and fused CT-MRI images can provide more information and improve the precision of target volume delineation.

More
广告
  • 浏览360
  • 下载92
中华放射肿瘤学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷