医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

3D打印多通道施源器在宫颈癌术后患者近距离治疗中研究

Study of 3D-printed multi-channel applicator in patients treated with brachytherapy after cervical cancer surgery

摘要目的:比较3D打印多通道施源器与常规阴道单通道施源器用于近距离治疗的剂量学差异,为宫颈癌术后患者的近距离治疗提供一定的指导依据。方法:选取25例自2019年1月—2020年11月接受 192Ir高剂量率近距离治疗的宫颈癌术后合并阴道上皮内瘤变Ⅲ级的患者,每位患者均采用3D打印多通道施源器和常规阴道单通道施源器进行CT扫描定位,并制定相应计划及评估,运用逆向剂量优化算法计算后得出剂量体积直方图,比较两组施源器用于近距离治疗时的高危临床靶区、膀胱及直肠受照剂量的差异,选择最优计划实施治疗。 结果:采用3D打印个体化多通道施源设计计划的D 90%、D 100%、V 100%、V 150%与常规单通道施源器设计的计划相比,差异均无统计学意义( P>0.05);膀胱、直肠的D 2cm 3与常规相比均明显降低,差异有统计学意义(均为 P<0.05)。 结论:采用3D打印技术制作的多通道个体化施源器靶区适形性好,可更好地保护膀胱和直肠,有一定的治疗优势。

更多

abstractsObjective:To compare the dosimetric difference between 3D-printed multi-channel applicator and conventional vaginal single-channel applicator for brachytherapy, aiming to provide guidance for patients receiving brachytherapy after cervical cancer surgery.Methods:From January 2019 to November 2020, 25 cervical cancer patients complicated with VAIN Ⅲ receiving 192Ir high-dose-rate brachytherapy after cervical cancer surgery were selected. Each patient was located by CT scanning with 3D-printed multi-channel applicator and conventional vaginal single-channel applicator, and corresponding plan and evaluation were carried out. The dose volume histogram (DVH) was obtained by inverse dose optimization algorithm. The dosimetric differences of high-risk clinical target volume (HRCTV), bladder and rectum during brachytherapy were compared with those of source applicators. The optimal treatment plan was selected. Results:D 90%, D 100%, V 100% and V 150% of the plans designed by 3D-printed individual multi-channel applicator had no significant differences compared with those designed by conventional single-channel applicator (all P>0.05). The bladder and rectal D 2cm 3 designed by 3D-printed multi-channel applicator were significantly lower than those using conventional single-channel applicator, and the differences were statistically significant (both P<0.05). Conclusion:The multi-channel individual applicator target made by 3D-printing technology has good conformal property, properly protects the bladder and rectum and possesses treatment advantages over conventional single-channel applicator.

More
广告
  • 浏览172
  • 下载2
中华放射肿瘤学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷