前臂骨间膜的解剖及生物力学研究

An anatomical and biomechanical study of the forearm interosseous membrane

摘要目的 探讨前臂骨间膜(interosseous membrane,IOM)的解剖及生物力学特性.方法 从10个新鲜冰冻上肢标本中取出尺桡骨连同骨间膜结构,测量腱性部分的长度、宽度及厚度.测量完毕后将骨间膜腱性部分同其尺桡骨附着端一并分离,将标本的桡骨近端及尺骨远端分别用牙托粉包埋固定,标本夹持固定于MTS 858型生物材料试验机上.使用10000N力传感器进行测定,以50mm/min的速度拉伸骨间膜,直至骨间膜断裂.通过计算机采集数据描绘载荷一位移曲线,同时测定骨间膜的最大载荷和刚度.结果 (1)前臂骨间膜由三部分组成:中央腱性部分、两端膜性部分及背侧附属斜索.3个标本中未观察剑背侧附属斜索.骨间膜在前臂中立位时伸展,在前臂旋前及旋后时弯曲.(2)6个标本发生骨间膜腱性部分撕裂,最大载荷为(1021.50+250.13)N,刚度为(138.24±24.29)N/mm,骨间膜的拉伸长度为(9.77+1.77)mm;4个标本在腱性部分撕裂之前发生尺骨固定端骨折,最大载荷为(744.40+109.85)N,刚度为(151.17+30.68)N/mm,骨间膜的拉伸长度为(6.51+0.51)mm.结论 前臂骨间膜是尺桡骨之间具有韧带性质的结构,对维持前臂的纵向稳定至关重要.其解剖学及生物力学数据可以作为评估前臂骨间膜重建方法的客观标准.

更多

abstractsObjective To observe the anatomical and biomechanieal properties of the forearm in terosseous membrane (IOM), providing the scientific theoretical basis for the diagnosis and treatment of the IOM injury. Methods Ten radius-IOM-ulna structures (left for 5 and right for 5) were harvested from 5 fresh-frozen adult cadavers to measure the length, width and thickness of the tendinous part. Then the tendi-nous part with its radial and ulnar insertions were isolated, embedding the proximal part of the radius and the distal part of the ttina in commercially available dental base acrylic resin powder. The embedded speci-mens were mounted on MTS 858 testing machine using a 10 000 N load cell for all tensile tests. The speci-mens were tested at a displacement rate of 50 mn/min until failure. The load-displacement curve was de-scribed by the computer while the maximum load and stiffness were recorded. Results The IOM consisted of three components: the tendinous part, the membranous part, and the dorsal oblique accessory cord. The IOM was fiat in the neutral position, while it flexed during the pronation and supination. Six specimens ob-tained the tear of tendinous portion at a maximum load of (1021.50±250.13) N. The stiffness was (138.24±24.29) N/mm with displacement to failure of (9.77±1.77) mm. Other 4 specimens failed by fracture through the ulnar fixed site before there was failure of the IOM at a maximum load of (744.40±109.85) N. The stiff-ness was (151.17±30.68) N/mm with displacement to failure of (6.51±0.51) ram. Conclusion The IOM has stiffness comparable to the ligament between the radius and the ulna and play an important role for the maintenance of longitudinal stability of the forearm. These results can provide objective criteria for the eval-uation of reconstructive methods.

More
广告
分类号 R6
栏目名称 临床研究
DOI 10.3760/cma.j.issn.0253-2352.2009.06.013
发布时间 2009-06-30
基金项目
浙江省医药卫生科学研究基金计划
  • 浏览423
  • 下载173
中华骨科杂志

中华骨科杂志

2009年29卷6期

572-575页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷