医院内军团菌肺炎暴发六例分析

Outbreak of six cases of nosocomial Legionella pneumophila pneumonia

摘要目的 分析医院内暴发性军团菌肺炎的临床特点、诊治过程及暴发原因.方法 回顾性分析6例医院内暴发性军团菌肺炎的临床资料、诊疗过程及暴发原因.结果 6例患者均为武警后勤学院附属医院呼吸与重症医学科医护人员,年龄23 ~ 27岁,男1例,女5例,通过尿军团菌1型抗原检测阳性而确诊,感染源系医院空调系统水被军团菌污染所致.6例均发热,体温为37.5 ~39℃,咳嗽及咳痰,1例有纳差、胸闷、胸痛,3例伴头痛,3例肺部可闻及湿性啰音.胸部CT表现为单发或多发小斑片状阴影.无相对缓脉、低钠血症、低磷血症及腹泻等典型消化道症状,也未出现肾脏以及神经系统等的典型肺外表现.结论 本组资料提示,军团菌肺炎临床表现为轻度肺炎,实验室检查电解质在正常范围,影像学表现为双肺或单肺多发小斑片状阴影,与病毒性肺炎易混淆,应注意鉴别.军团菌可来自中央空调系统、热水管道系统,通过呼吸道传播而暴发,应加强医院空调系统的病原菌监测及清洁,防控军团菌医院内感染的暴发.

更多

abstractsObjectives To describe the clinical characteristics,diagnosis,treatment and the causes of outbreak of nosocomial pneumonia due to Legionella pneumophila.Methods The medical records of 6 cases of nosocomial Legionella pneumophila pneumonia were retrospectively reviewed,and the clinical data of clinical presentation,treatment,and etiologic diagnosis were analyzed.Results The 6 patients were health care providers of the Department of Respiratory and Critical Care Medicine of the Affiliated Hospital of Logistics University of PAPF.There were 5 female and 1 male patients,aged 23 to 27 years.The diagnosis of Legionella pneumonia was made based on a positive Legionella urinary Ⅰ antigen test.In all the 6 cases,the disease was attributable to inhaling contaminated aerosols produced by the air conditioning system in our hospital.All the 6 patients presented with fever of 37.5-39 ℃,and productive cough.One patient had anorexia,dyspnoea,and pleuritic chest pain,while headache was reported in 3 patients.Physical examinations revealed lung rales in 3 patients.Single or multiple patchy infiltrates were found on Chest CT in all patients.However,the typical extrapulmonary manifestations of Legionnaires' disease,including relative bradycardia,hyponatremia,hypophosphatemia and diarrhea,were not present in the 6 patients.Neither neurological abnormalities nor renal involvement were observed.Conclusions Our data demonstrated that Legionella pneumonia may be mild with atypical laboratory findings and clinical manifestations,with fever,cough,chest tightness,headache,etc.The radiologic manifestations of Legionella pneumonia were single or multiple patchy infiltrates,similar to those of viral pneumonia,and therefore their differential diagnosis was needed.Legionella pneumophila can outbreak through the respiratory tract,in public places with central airconditioning system,hot water piping systems and hospitals,and therefore microbiological monitoring,cleaning and disinfection of the water system was required for prevention of the outbreaks of Legionnaires' disease.

More
广告
栏目名称
DOI 10.3760/cma.j.issn.1001-0939.2015.04.013
发布时间 2015-04-30(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览373
  • 下载712
中华结核和呼吸杂志

中华结核和呼吸杂志

2015年38卷4期

294-297页

MEDLINEISTICPKUCSCD

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷