• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

四种自酸蚀粘接剂牙本质粘接界面纳米渗漏比较

Nanoleakage at the resin-dental interface of four self-etching adhesives

摘要目的 比较4种自酸蚀粘接剂牙本质粘接界面纳米渗漏及微观形态。方法 选取16颗无龋人离体第三磨牙,制备统一的牙本质玷污层,分别用4种自酸蚀粘接剂A( Adper Prompt)、B( iBond)、C(XenoⅢ)及D(SE Bond)按使用说明进行粘接处理,垂直粘接面切成0.9 mmx4.0 mm试件,避光贮存于氨化硝酸银溶液中24 h,经显影固定脱矿后,切成90 nm超薄切片,铀、铅染色后于透射电镜下观察银离子的渗入情况及界面相关结构。结果4种粘接剂形成的混合层及粘接层薄厚不同:粘接剂A、C混合层较B、D厚,粘接层较B、D簿。4种粘接剂粘接界面均有不同程度纳米渗漏:A(45.02 ±9.49);B(43.97±8.55);C(27.02±10.86);D(12.94±2.07)。粘接剂D组纳米渗漏较小,与其他3种粘接剂间差异有统计学意义(P<0.05)。结论4种自酸蚀粘接剂混合层和粘接层厚度存在差异,粘接界面的纳米渗漏率不同,一步法自酸蚀粘接系统纳米渗漏较两步法系统明显。

更多

abstractsObjective To evaluate the nanoleakage and ultramorphology of four self-etching adhesives. Methods Sixteen freshly extracted, caries-free human third molars were selected. A flat dentin surface was exposed by removing occlusal enamel. All teeth were randomly divided into four groups acorrding to four different self-etch adhesive: Adper Prompt( A), iBond(B) , Xeno Ⅲ (C) and SE Bond (D). The dentin were bonded with dentin adhesive system according to manufacturer's directions. Composite layers were built up incrementally. The specimens were sectioned longitudinally across the resin-dentin interface into 4. 0 mm × 0. 9 mm sticks and then traced with ammoniacal silver .solution. Epoxy resin-embedded sections were prepared for transmission electron microscope( TEM ) to observe nanoleakage. The images were qualitatively compared by NIH software, and data was analyzed by SPSS. Results Different thickness of hybrid layer and adhesives layer were observed for each adhesive. The hybrid layer of A, C was thicker than that of B, D, and adhesive layer of D was thicker than the others. The extent of nanoleakage varied among different adhesives: A (45.02 ±9.49),B (43.97 ±8.55), C(27.02 ± 10.86), D (12.94 ±2.07). D presented significantly less silver deposition than any of the others did (P < 0. 05 ). Conclusions The thickness of hybrid layer and adhesive layer vary among the four adhesives. The shape and extent of nanoleakage of each adhesive are also different. Two-step system shows less nanoleakage than one-step systems do.

More
广告
  • 浏览347
  • 下载166
中华口腔医学杂志

中华口腔医学杂志

2011年46卷9期

554-557页

MEDLINEISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷